4
TECHNICAL PASSPORT, INSTALLATION AND MAINTENANCE MANUAL
• Use only recommended fuel type.
• Turn of the boiler in case of danger of explosion, fire, formation of flammable gases or vapours.
DANGER
Flammable substances or liquids may ignite.
• It is forbidden to store flammable substances and liquids near the boiler.
• Respect the indication of minimum distance between the boiler and easily flammable materials
1.4
User advice
ATTENTION!
• Boiler can only be operated by adults who are familiar with the boiler’s user manual.
• It is forbidden to leave children unattended at a running boiler.
• Boiler’s operating temperature must not exceed 85 °C.
• It is forbidden to use liquid for boiler ignition or to increase the power of a boiler.
• Removed ash should be placed in a nonflammable tank with a cover.
• Only non-combustible materials may be used to clean heated boiler surfaces.
• It is forbidden to place flammable items on or near the boiler (safe distance must be respected).
• It is forbidden to store flammable materials on the boiler (for example, wood, paper, oil).
1.5
Minimum distance and flammability of materials
Recommended minimum distance may vary in different countries from the following indications. It can
be learnt by asking your local installer or chimney sweep.
•
Minimum distance from boiler wall and chimney to material of average or high flammability must be
at least 400 mm.
•
Minimum distance from flammable materials must be at least 600 mm. If flammability is unknown,
600 mm distance must be preserved.
Flammability of materials
A – non-flammable
Asbestos, rocks, bricks, ceramic tiles, calcined clay, construction mortar,
plaster (without organic additives)
B – not easily flammable
Plaster cardboard panels, basalt felt mats, panels AKUMIN, IZOMIN,
RAJOLIT, “lignos”, VELOX and “Heraclitus”
C1 – hardly flammable
Felt mat covered with beech wood or oak wood, panels HOBREX,
VERZALIT, “Formica”
C2 – moderately flammable
Pine, larch and spruce wood, as well as coated products thereof
C3 – flammable
Asphalt, cardboard, cellulose materials, bituminized paper, hard panels,
cork, polyurethane, polystyrene, polypropylene, polyethylene, hay
1.6
Cleaning and installation tools
The installation of the boiler requires conventional tools used by heating, liquid fuel and water system
installers.
To maintain the boiler usual tools used at home, such as a shovel, broom, spade, are required. When
cleaning the boiler, use a brush, poker and scraper, ash pump.
We recommend that you call a competent person for inspection / service of the boiler at least two times
a year before and after the heating season.