5. Insert jack handle into handle socket and pump until ram nears work piece. Align ram and work piece
to ensure center-loading. Apply load to work piece by pumping handle. Do not overload work piece
.
6. Keep ram and work piece aligned to ensure center-loading.
7. When work is completed, stop pumping the handle. Stabilize the work piece in a manner which will
not allow it to inadvertently fall from the bed frame once the load is removed, then slowly turn the
release valve counter-clockwise in small increments until ram is free from work piece.
Once ram has fully retracted, remove work piece from bed frame. Cautiously remove work piece
from press.
Summary of Contents for 46260
Page 23: ...23 ASSEMBLY DIAGRAM ...