2.
Using the template provided work out where best to secure this unit on to the wall ensuring that it is
level. Mark up the drill holes through the holes in the template then drill through and place wall plugs
into the holes. Offering your unit up to the wall and screw into the corresponding holes on the unit to
the holes on the wall and ensure the unit is secure on the wall.
3. We suggest fitting an isolation valve or ball valve before the tap to facilitate removal of the unit
and servicing. Connect your cold mains supply to the internal ½” thread’s making sure that the flow
reducing washer provided is fitted the correct way around between the nut and threads.
4.
Make the correct electrical connections to the unit, but do not turn the power back on at this stage. A
minimum heat resistance cable size of 1.5mm² should be used. The product can be connected in two
different ways:
•
Via a fused and switched connection unit taken as a spur from a 13amp ring main.
•
As a separate circuit taken directly from a spareway in a consumer unit.
In each case a double pole isolating switch having a contact separation of at least 3mm in each pole,
and a minimum rating of 13amp must be incorporated in the wiring of the appliance.
5. Before replacing the front cover of the unit make sure that there are no leaks from the cold inlet
connection. Place the front cover back on to the unit whilst still ensuring the temperature control dial
is still in the off position. Finally replace the screws at the base of the unit.
REMEMBER:
Before turning off the water supply to the unit you must isolate its electric supply, operating
the tap while there is no water can cause premature failure and invalidate your warranty.
DO NOT
turn on
your electric supply at this time.
C O M I S S I O N I N G
1.
Flush the unit completely for 20 seconds, to do this turn the control dial to the fully open cold position,
in the case of the automatic model please restore power to the unit only when the control dial is in
the fully cold position.
2.
Once flushed for 20 seconds please move the control dial to the off position and in the case of the
manual model please also restore power.
3.
To set the flowrate and temperature of the unit please set the control dial to the midway position on
the hot side.
4.
Whilst in this position please restrict water flow to the unit using the isolating valve fitted before
the unit. Restricting the flow will increase the output temperature, whilst increasing the flow will
decrease the temperature.
5.
Once the required temperature is achieved please set control dials on manual models to the off
position, and set automatic models to the correct temperature ready for use.
6.
Your HandyWash is now ready for use.