background image

2. 

Using the template provided work out where best to secure this unit on to the wall ensuring that it is 
level. Mark up the drill holes through the holes in the template then drill through and place wall plugs 
into the holes. Offering your unit up to the wall and screw into the corresponding holes on the unit to 
the holes on the wall and ensure the unit is secure on the wall. 

3.  We suggest fitting an isolation valve or ball valve before the tap to facilitate removal of the unit 

and servicing. Connect your cold mains supply to the internal ½” thread’s making sure that the flow 
reducing washer provided is fitted the correct way around between the nut and threads. 

4. 

Make the correct electrical connections to the unit, but do not turn the power back on at this stage. A 
minimum heat resistance cable size of 1.5mm² should be used. The product can be connected in two 
different ways:

• 

Via a fused and switched connection unit taken as a spur from a 13amp ring main.

• 

As a separate circuit taken directly from a spareway in a consumer unit.

 

In each case a double pole isolating switch having a contact separation of at least 3mm in each pole, 
and a minimum rating of 13amp must be incorporated in the wiring of the appliance.

5.  Before replacing the front cover of the unit make sure that there are no leaks from the cold inlet 

connection. Place the front cover back on to the unit whilst still ensuring the temperature control dial 
is still in the off position. Finally replace the screws at the base of the unit.

REMEMBER:

 Before turning off the water supply to the unit you must isolate its electric supply, operating 

the tap while there is no water can cause premature failure and invalidate your warranty. 

DO NOT

 turn on 

your electric supply at this time.

C O M I S S I O N I N G

1. 

Flush the unit completely for 20 seconds, to do this turn the control dial to the fully open cold position, 
in the case of the automatic model please restore power to the unit only when the control dial is in 
the fully cold position.

2. 

Once flushed for 20 seconds please move the control dial to the off position and in the case of the 
manual model please also restore power.

3. 

To set the flowrate and temperature of the unit please set the control dial to the midway position on 
the hot side.

4. 

Whilst in this position please restrict water flow to the unit using the isolating valve fitted before 
the unit. Restricting the flow will increase the output temperature, whilst increasing the flow will 
decrease the temperature.

5. 

Once the required temperature is achieved please set control dials on manual models to the off 
position, and set automatic models to the correct temperature ready for use.

6. 

Your HandyWash is now ready for use.

Summary of Contents for HANDYWASH SEHW3KA1

Page 1: ...S E H W 3 K M 1 S E H W 3 K A 1 I n s t a l l a t i o n M a n u a l I s s u e 1 2 0 1 7 S E H W 3 K A 1 M o d e l S h o w n STROM LIMITED www stromltd com H A N D Y W A S H...

Page 2: ...ated Current 13A Recommended Cable Size 1 5mm2 Thermal Cut Out 65o C Dry Heating Protection 70o C Hot Water Flow 0 5L 2L Per Minute Dependent On Required Temp IP Rating IPX4 Working Pressure 0 2 6 Bar...

Page 3: ...d be assessed by a qualified electrician and the device should not be used until the unit or wiring has been repaired The minimum water supply available at the point of install is 0 2 Bar If at any ti...

Page 4: ...Arm Electrical Terminal Block Water Valve Block Micro Switch Heating Element Thermal Cut Out Water Inlet Water Spray Arm Electrical Terminal Block PCB Cover Micro Switch Heating Element Thermal Cut Ou...

Page 5: ...nd laws in place at the time of installation ACTION 1 ACTION 2 ACTION 3 1 To connect the Sprayer Spout start by ensuring the temperature control dial is set in the off position Remove the two screws a...

Page 6: ...over of the unit make sure that there are no leaks from the cold inlet connection Place the front cover back on to the unit whilst still ensuring the temperature control dial is still in the off posit...

Page 7: ...he tap Turning the temperature dial towards hot will give you hot water the further towards hot you turn the temperature dial the faster hot water will come out of the tap however the higher the flow...

Page 8: ...of 12 months from the date of purchase The unit is only guaranteed if the water heater has been installed and maintained in accordance with these instructions Full guarantee information can be found...

Page 9: ...NOTES...

Page 10: ...NOTES...

Page 11: ...NOTES...

Page 12: ...w w w s t r o m l t d c o m STROM LIMITED www stromltd com...

Reviews: