16
BA_KA-ED_A22_190313_en.doc
3.5
Pneumatic connection
Each half of the machine is separately connected pneumatically by an 8/6-PA hose to a
connector plug. The maintenance unit is set to 5 to 6 bar operational pressure.
Minimum operational pressure 5 bar.
3.6
Power supply
C A U T I O N ! Danger of injury!
Work on the electrical equipment may be done only by electricians or
properly trained technicians. The exists the risk of fatal electrical
shock.
The electrical connection is separate for each machine half.
A T T E N T I O N !
Before connecting the machine electrically be sure that the local
network voltage and the net frequency corresponds to the machine.
Network voltage and network frequency can be found on the type
sign on the back side of the machine stand.
If network voltage and frequency are not compatible, the electrical
installation of the machine will be destroyed.
3.7
Check light barriers
-
Mirror (1) (S8-1) and (2) (S8-2) along the entire length and check for damages.
-
Push carriage manually to the middle.
-
Switch on main switch S0.
-
Press the START button S4 (carriage moves to basic position).
-
Press START button S4 again (clamping device closes).
-
Switch toggle switch S6 to “
” position (“0” position) (carriage can be moved
freely by hand) (Fig. 10).
-
Keep an eye on the LED of the light barriers S8-1 and S10 and push the carriage
through slowly by hand. The LED’s should bit lit without interruption along the
entire length; otherwise re-adjust
(see point “5.2 Setting the light barriers (Fig. 16a + Fig. 17)”).
Machine is ready for sewing.