Installation 

• Mark  two  holes  on  the  wall,  indicating  the  position  that  you  want  to  install  the 

heaters. The different distances between the respective holes are: 

• Single element models: 300 mm 
• Double element units: 660 mm 

• The recommended 

installation height

 is as follows: 

• 1500 watt models: 1,8 m — 2,5 m above floor height 
• 3000 watt models: 2500 mm — 4000 mm above floor height  
• Ensure that you adhere to 

all safety distances

 as per the diagram in this manual. 

• Drill a 6 mm hole about 70 mm deep on both positions 
• Fix the L-bend wall brackets using the supplied 6 mm anchor screws. The slotted part 

of  the  bracket  goes  against  the  wall  and  the  5  mm  hole  against  the  heater. 

Do  not 

tighten the bracket yet. 

• If you mount the heater on wood, or drywall, etc., ensure that you use the

 appropriate 

screws and isolation between the bracket and the surface.

 

• Fix the heater to the wall brackets using the supplied M5 washer and hex bolt. Move 

the wall brackets either left or right in the slot to ensure a tight fit. 

• Swivel the heater to the desired position and tighten the bolts. 
• Connect the electrical wire to the supply as per building regulations. 

Installation on a portable stand 

Do  not

  use  this  heater  in  the  immediate  surroundings  of  a  bath,  a  shower  or  a 

swimming pool. 

Do  not

  use  the  portable  stand  indoors  or  near  any  combustible  materials,  couches, 

carpets, etc. 

• Ensure that the electrical cable is secure and not crossing any walkways. 
• Remove any wall brackets from the heater 
• Fit the Supplied stand bracket to the centre of the heater using the M5 Hex screw. 
• Fit the complete unit on the stand using the M10 wing nut 
• Let the heater 

cool down for 5 minutes 

before you move the stand. 

Page 

!

 of 

!

                                   www.striking.co.za

 

           

[email protected]

 

7

12

Summary of Contents for G3 1000 G

Page 1: ...Page of www striking co za info striking co za 1 12 Instructions G3 Model ...

Page 2: ... way Features Light and durable Completely rust free units are constructed from high grade aluminium and stainless steel Elements are quick and easy to replace Easy installation Improved and unique reflector design converts 98 electrical energy into heat short wave 5 year warranty on the body 1 year warranty on electronics Integrated uni body reflector Manufactured in South Africa Parts available ...

Page 3: ...crete Ensure proper insulation when installing on a wooden surface The minimum ventilation openings around the heater after installation must be between 10 cm and 20 cm from the top and sides and at least 150 cm away from any combustible materials curtains paper etc Remove the foam that protects the lamp during transit before operating the heater The heater MUST be installed above 1 8 m from the f...

Page 4: ...are removed from box Never touch the element For cleaning purposes use an alcohol base cleaner Choosing your position There are a number of products and installation methods you can choose from Understanding the characteristics of infrared heat will assist you in selecting your ideal position This is not an exact science and the averages discussed here should be more than sufficient Page of www st...

Page 5: ...erms of cost to rather use a 3000 watt heater at a height of 3 5 m to cover an area than 2 x 1500 watt heaters at the same height Current available Each 1500 watt heater draws about 8 ampere while a 3000 watt heater draws about 16 ampere A typical residential trip switch can accommodate 2 x 1500 watt heaters or 1 x 3000 watt heater If you require more than that you will have to run a separate supp...

Page 6: ... Page of www striking co za info striking co za 6 12 Limited Ventilation on all heaters Do not mount heaters facing straight down in areas with limited ventilation Always ensure that heaters are mounted on non combustable material ...

Page 7: ...use the appropriate screws and isolation between the bracket and the surface Fix the heater to the wall brackets using the supplied M5 washer and hex bolt Move the wall brackets either left or right in the slot to ensure a tight fit Swivel the heater to the desired position and tighten the bolts Connect the electrical wire to the supply as per building regulations Installation on a portable stand ...

Page 8: ...T waterproof but is safe for using in a humid environment Disconnect the unit from the mains during installation when cleaning and or when replacing the element To avoid risk of burns always ensure that the element and heater body had sufficient time to cool down before cleaning Do not handle the halogen element with bare hands If it is inadvertently touched remove any and all finger marks with a ...

Page 9: ...ire through the hole 5 Tilt the heater facing downwards or should you prefer remove the heater from the brackets and place on an even surface 6 Unscrew the 2 screws at the back using the 3 mm Allen key Keep the M5 x 25 mm screws safe 7 Slowly pull the element out to the front while feeding the wires 8 Take the 2 spacing washers out that are on the element w ires and keep them safe Discard the elem...

Page 10: ...Original Model 3 Parts diagram and exploded view Updated Model 3 Parts diagram and exploded view Page of www striking co za info striking co za 10 12 ...

Page 11: ...eel Electrical requirements 230 Volt 50 Hz 1500 watt 7 Amp 230 Volt 50 Hz 3000 watt 14 Amp Overall Dimensions Width x Height x Depth 370 x 84 x 105 mm 730 x 84 x 105 mm Burning position Horizontal as well as vertical position Element Life Half life of 5000 hrs for Ruby and Gold Electrical Cable 3 Core 1 5 mm Silicone heat resistant cable Open ended 3 Core 2 5 mm Silicone heat resistant cable Open ...

Page 12: ...Updates to these instructions are available from our website Visit www striking co za VERSION 5 April 2017 Striking Energy Page of www striking co za info striking co za 12 12 ...

Reviews: