TURN OFF
1.
1. Press and turn the flow regulator to the "PILOT" position
2.
Press and turn the flow regulator to the "OFF" position
3.
Close the valve on the gas cylinder.
TROUBLESHOOTING
ISSUE
CAUSE
SOLUTION
THE IGNITION SPARK IS OFF
FLOW REGULATOR IS
COMPRESSED IN THE "PILOT"
POSITION
Improperly positioned lighter
electrode
Replace or position the igniter
electrode correctly
Broken lighter electrode
Replace the igniter electrode
Ignition cable pinched or broken
Loosen or replace the ignition
cable
IGNITION SPARK IS ON
FLOW REGULATOR IS
COMPRESSED IN THE "PILOT"
POSITION
BUT THE BURNER FLAME DID
NOT IGNITE
No gas supply
Secure the gas supply
Flow controller is not in "PILOT"
position
Set the flow regulator on the
"PILOT" position
The flow controller is in the
"PILOT" position but not pressed
Press the flow regulator
The ignition spark is clogged
Contact an authorized service
center
There is air in the gas pipe
Vent the piping by continuously
pressing the flow regulator until
you smell a faint gas odor
THE FLAME IS EXTINGUISHED
WHEN THE FLOW REGULATOR IS
RELEASED
The flow regulator has not been
pressed long enough.
Hold the flow regulator pressed
for at least 30 seconds
The ignition
spark does not
touch the
thermocouple.
Partially
clogged
ignition spark
nozzle
Contact an authorized service
center
Low gas
pressure
Damaged thermocouple
Replace the thermocouple.
Loose thermocouple connection
to flow controller
Tighten first by hand and then by
¼ turns with a
wrench
Damaged flow regulator
Replace the flow regulator
THE BURNER FLAME DON'T
IGNITE EVEN WHEN THE
IGNITION IS ON
Blocked burner nozzle
Clean or replace burner nozzle
Low gas supply pressure
Contact the gas cylinder
manufacturer or an authorized
service center
THE BURNER FLAME GOES OFF
AFTER THE IGNITION
Low gas supply pressure
After ignition, wait at least 10
minutes before setting the flow
regulator to the minimum
position "LO"
DELAYED IGNITION
Clogged burner
Clean the burner
Low gas supply pressure
Contact the gas cylinder
manufacturer or an authorized
service center
INSUFFICIENT COMBUSTION
Lack of air
Check that the ventilation
openings and the burner are not
blocked and clean them if
necessary
LOW BURNER FLAME
Bent or twisted gas hose
Adjust the hose and perform a