48
17.6
User Operation
You can conduct the operating steps described below on either a room unit or operator unit. Differences between the
information provided on the operator and room unit are limited to the following areas:
•
The room units start page (
) presents the values relevant to the room.
•
The operator units start page (
) focuses on producer information.
•
In the event of multiple room units, individual room units can be assigned to individual living zones.
•
Operator units are normally assigned to all living rooms.
Operating Tips:
Editing Timeout
5 seconds
A changed setting reverts to the original state if not confirmed within this
period.
Long Button
Pressure
≥ 3 seconds
A long press of the knob on any expert view returns to the "Expert view
start page" (diagnostics page).
Locking Timeout
1 minute
Certain plant states are displayed in the foreground, e.g. special
operations page. However, users are still able to go to any page and set
values. The foreground page returns after this period without operator
intervention.
Operating
Timeout
8 minutes
The display switches automatically after this period without operation to
the start page on the operator unit or display in standby on the room unit.
17.6.1
H
OME
S
CREEN
The below screen is the home screen from the controller in “operator mode.”
Flow Temperature = Current flow temperature to the thermal store /
buffer vessel.
Return Temperature = Current return temperature from the thermal
store / buffer vessel.
Outside Temperature = Current outside temperature.
DHW Temperature = Current DHW temperature within indirect
cylinder.