background image

Input voltage (Normal) 

AC Systems: 200-240 VAC 
DC Systems: -48 VDC 

Input voltage (Maximum) 

AC Systems: 264 VAC 
DC Systems: -60 VDC 

AC Input frequency 

AC Systems: 50-60Hz 
DC Systems: NA 

5.2 V128 LCD Display

 

 

Physical 

Height 

1.75 in. (4.45 cm; 1U)  

Width 

19 in. (48.3 cm) 

Depth 

24 in. (61 cm) 

Environmental 

Operating temperature 

32 F to 104 F (0 C to 40 C) 

Storage temperature 

-13 F

 to +140 F (-25 C to +60 C) 

Relative humidity during operation 

10% to 80% (noncondensing) 

Relative humidity during storage 

5% to 95% (noncondensing) 

Heat dissipation 

38 BTUs per hour 

 Electrical 

Output wattage 

21 W (AC) 

Input voltage 

90-265 volts AC; 47-63 Hz 

 

Summary of Contents for ftServer T30

Page 1: ...pendent of a cabinet 2 Operating System Requirements The ftServer T30 system is supported by the Stratus ft Linux operating system which is based on the Linux operating system with Stratus additions T...

Page 2: ...al Inline Memory Module DIMM memory in 256 MB and 512 MB configurations The minimum ftServer T30 logical memory is 512 MB and the maximum is 3 GB Up to six DIMMs can be housed in each CPU enclosure DI...

Page 3: ...n Min Max U574 2 port 1000Base Sx Fiber Gigabit Ethernet Adapter 0 4 U575 2 port 1000Base T Copper Gigabit Ethernet Adapter 0 4 U917 VGA Adapter 2 2 U918 4 port T1 E1 Adapter For SINAP 0 4 3 2 2 SCSI...

Page 4: ...oppy Disk Drive Modem 3 5 1 Tape Drives ftServer T30 systems support DDS 4 tabletop tape drives No tape drives are mounted in the cabinet They are all external to the cabinet The following table lists...

Page 5: ...a a USB port 3 5 4 Modem The C719 an external serial 56K Data Fax MultiTech ZBA modem is used to connect to the Stratus ActiveService Network ASN 4 System Configuration Marketing ID P5101R 2D Processo...

Page 6: ...40 C to 70 C Unvented 40 C to 60 C Vented Operating Altitude 0 to 10000 ft 0 to 3048 m Maximum rate of temp change during operation 12 C Hour Relative humidity during operation 5 to 85 Non condensing...

Page 7: ...ical Height 1 75 in 4 45 cm 1U Width 19 in 48 3 cm Depth 24 in 61 cm Environmental Operating temperature 32 F to 104 F 0 C to 40 C Storage temperature 13 F to 140 F 25 C to 60 C Relative humidity duri...

Page 8: ...35 C Storage temperature 41 F to 113 F 5 C to 45 C Relative humidity during operation 30 to 80 noncondensing Relative humidity during storage 5 to 90 noncondensing Heat dissipation 103 BTUs per hour...

Page 9: ...Nominal input voltage Frequency 100 240 volts AC 50 60 Hz Physical Height 3 7 in 95 mm Width 4 6 in 116 mm Depth 8 7 in 220 mm Weight 4 6 lb 2 1 kg 5 7 T512 DDS 4 DAT Tape Drive with Autoloader Power...

Page 10: ...Server T30 Installation Guide R002L Stratus ftLinux System Administrator s Guide R003L Stratus ftServer T30 Operation and Maintenance Guide R004L Release Notes Stratus ftLinux Release 2 1 R005L Read M...

Reviews: