background image

S

AFETY

 I

NFORMATION

S

YSTEM

 A

CCESS

 W

ARNINGS

 

3

-4

Power Cord Warnings

If an AC power cord was not provided with your product, pur-
chase one that is approved for use in your country.

System Access Warnings

CAUTION!

T

O

 

AVOID

 

ELECTRICAL

 

SHOCK

 

OR

 

FIRE

CHECK

 

THE

 

POWER

 

CORD

(

S

THAT

 

WILL

 

BE

 

USED

 

WITH

 

THE

 

PRODUCT

 

AS

 

FOLLOWS

:

Do not attempt to modify or use the AC power cord(s) if 
they are not the exact type required to fit into the grounded 
electrical outlets.

The power cord(s) must meet the following criteria:

The power cord must have an electrical rating that is greater 
than that of the electrical current rating marked on the prod-
uct.

CAUTION!

T

HE

 

POWER

 

CORD

 

MUST

 

HAVE

 

SAFETY

 

GROUND

 

PIN

 

OR

 

CONTACT

 

THAT

 

IS

 

SUITABLE

 

FOR

 

THE

 

ELECTRICAL

 

OUTLET

.

CAUTION!

T

HE

 

POWER

 

SUPPLY

 

CORD

(

S

IS

 / 

ARE

 

THE

 

MAIN

 

DISCONNECT

 

DEVICE

 

TO

 AC 

POWER

. T

HE

 

SOCKET

 

OUTLET

(

S

MUST

 

BE

 

NEAR

 

THE

 

EQUIPMENT

 

AND

 

READILY

 

ACCESSIBLE

 

FOR

 

DISCONNECTION

.

CAUTION!

T

HE

 

POWER

 

SUPPLY

 

CORD

(

S

MUST

 

BE

 

PLUGGED

 

INTO

 

SOCKET

-

OUTLET

(

S

THAT

 

IS

 /

ARE

 

PROVIDED

 

WITH

 

A

 

SUITABLE

 

EARTH

 

GROUND

.

!

!

!

!

CAUTION!

T

O

 

AVOID

 

PERSONAL

 

INJURY

 

OR

 

PROPERTY

 

DAMAGE

THE

 

FOL

-

LOWING

 

SAFETY

 

INSTRUCTIONS

 

APPLY

 

WHENEVER

 

ACCESSING

 

THE

 

INSIDE

 

OF

 

THE

 

PRODUCT

:

Turn off all peripheral devices connected to this product.

Turn off the system by pressing the power button to off.

Disconnect the AC power by unplugging all AC power 
cords from the system or wall outlet.

Disconnect all cables and telecommunication lines that are 
connected to the system.

Retain all screws or other fasteners when removing 
access cover(s). Upon completion of accessing inside the 
product, refasten access cover with original screws or fas-
teners.

Do not access the inside of the power supply. There are no 
serviceable parts in the power supply. Return to manufac-
turer for servicing.

Power down the server and disconnect all power cords  
before adding or replacing any non hot-plug component.

When replacing a hot-plug power supply, unplug the power 
cord to the power supply being replaced before removing the 
power supply from the server.

CAUTION!

I

F

 

THE

 

SERVER

 

HAS

 

BEEN

 

RUNNING

ANY

 

INSTALLED

 

PROCES

-

SOR

(

S

AND

 

HEAT

 

SINK

(

S

MAY

 

BE

 

HOT

.

!

!

Summary of Contents for S210-X22RQ

Page 1: ...Version 1 0 STRATOS S210 Series S210 X22RQ Two Socket High Memory 2U Rackmount Server 8VHU V Guide...

Page 2: ...denotes keyboard keys WARNING Warning information appears before the text it references and should not be ignored as the content may prevent damage to the device CAUTION CAUTIONS APPEAR BEFORE THE TE...

Page 3: ...AT compatible region of battery backed 128 bytes of mem ory which normally resides on the baseboard CPU Central Processing Unit Deasserted A signal is deasserted when in the inactive state Active low...

Page 4: ...y Ms Milliseconds Mux Multiplexer NIC Network Interface Card NMI Nonmaskable Interrupt NM Node Management OBF Output buffer OEM Original Equipment Manufacturer Ohm Unit of electrical resistance PDB Po...

Page 5: ...rver Management Interrupt SMI is the highest priority nonmaskable interrupt SMM Server Management Mode SMS Server Management Software SNMP Simple Network Management Protocol SOL Serial Over LAN UART U...

Page 6: ...ystems networks and modems attached to the server before opening it Otherwise personal injury or equipment damage can result Electrostatic discharge ESD and ESD protection ESD can damage drives boards...

Page 7: ...SAFETY INFORMATION to grip with but not squeeze the pliers or other tool used to remove a jumper or the pins on the board may bend or break...

Page 8: ...this document is subject to change without notice The manufacturer makes no representations or warran ties with respect to the contents hereof and specifically dis claims any implied warranties of me...

Page 9: ...About the Server Chapter 1...

Page 10: ...rofile riser slot optional or 2 PCIe x8 G3 low profile riser slots optional 4 PCI x8 G3 low profile riser slots and 1 PCIe x4 G3 low profile riser slot 1 PCIe x8 G3 Network Mezzaine card slot and 1 PC...

Page 11: ...AS 2108 Mezzanine card optional Quanta LSISAS 2208 Mezzanine card optional Quanta LSISAS 2308 Mezzanine card optional System Memory 24 DDR3 800 1066 1333 1600 1866 MHz ECC RDIMM LR DIMM slots up to 76...

Page 12: ...8 PD 32 mezzanine card LSI RAID 6 Key for RAID 0 1 10 5 6 50 60 optional Quanta LSISAS2208 PD 32 mezzanine card for RAID 0 1 10 5 optional Quanta LSISAS2208 PD 32 mezzanine card LSI RAID 6 Key for RAI...

Page 13: ...CKAGE CONTENTS 1 4 Package Contents The following list includes the package components 1 2U chassis system 2 Processor heat sinks 1 2 Power supplys Optional 1 2 Power cords Optional 1 CD user manual i...

Page 14: ...16 G3 low profile riser slot or 1 PCIe x8 G3 low profile riser slots 1 PCI x8 G3 low profile riser slots and 1 PCIe x4 G3 low profile riser slots 2 PCIe x8 G3 low Profile riser slots and 1 PCIe x4 G3...

Page 15: ...s 1 PCI x8 G3 low profile riser slots and 1 PCIe x4 G3 low profile riser slots 2 PCIe x8 G3 low Profile riser slots and 1 PCIe x4 G3 low profile riser slots 1 PCIe x8 G3 10GbE SFP Mezzaine card slot a...

Page 16: ...S 1 7 System Front Features 3 5 HDD System Front Features Figure 1 3 3 5 HDD System Front Features 2 1 Table 1 2 3 5 HDD System Component Description NO ITEM DESCRIPTION 1 Front control panel Node con...

Page 17: ...ONT FEATURES 1 8 2 5 HDD System Front Features Figure 1 4 2 5 HDD System Front Features 2 1 Table 1 3 2 5 HDD System Component Description NO ITEM DESCRIPTION 1 Front control panel Node control system...

Page 18: ...Lights for system identification 6 Power Button Based on System Off Push Button to PSU and System on Based on System Off Push Button to PSU and System off 7 Identification Button Push to activate ID...

Page 19: ...rip OFF SEL Cleared DC Off Last pending warning or error has been de asserted HDD Activ ity Green Blinking Hard disk drive access only on board SATA port OFF No access non SAS LAN1 LED Green ON Link G...

Page 20: ...power supply unit Left PSU1 Right PSU0 2 PSU Connector Insert power supply cord 3 ID LED Lights for system identification 4 VGA port Connect a monitor to this port 5 Console port 6 USB port USB ports...

Page 21: ...ec OFF OFF link speed is 10Mbits sec LAN2 LED left Link Act Green ON LAN Link Green Black Blinking LAN Access off when there is traffic OFF Disconnect Speed Green ON Green link speed is 1000Mbits sec...

Page 22: ...Installation and Assembly Safety Instructions Chapter 2...

Page 23: ...ied AC power cord if it is not the exact type required A product with more than one power supply will have a separate AC power cord for each supply The power button on the system does not turn off sys...

Page 24: ...ge ESD protection by wearing an antistatic wrist strap attached to chassis ground of the system any unpainted metal surface when handling compo nents 6 Do not operate the system with the chassis cover...

Page 25: ...heck that cables add in cards and other components are properly installed 3 Attach the covers to the chassis with the screws removed earlier and tighten them firmly 4 Insert and lock the padlock to th...

Page 26: ...o a surge suppressor and disconnect telecommunication lines to your modem during an electrical storm Provided with a properly grounded wall outlet Provided with sufficient space to access the power su...

Page 27: ...Safety Information Chapter 3...

Page 28: ...omponents will void the UL List ing and other regulatory approvals of the product and may result in noncompliance with product regulations in the region s in which the product is sold Safety Warnings...

Page 29: ...lines to your modem during an electrical storm Provided with a properly grounded wall outlet Provided with sufficient space to access the power supply cord s because they serve as the product s main...

Page 30: ...ADD OR REMOVE ANY NON HOT PLUG COMPONENTS CAUTION DO NOT ATTEMPT TO MODIFY OR USE AN AC POWER CORD IF IT IS NOT THE EXACT TYPE REQUIRED A SEPARATE AC CORD IS REQUIRED FOR EACH SYSTEM POWER SUPPLY CAU...

Page 31: ...INTO SOCKET OUTLET S THAT IS ARE PROVIDED WITH A SUITABLE EARTH GROUND CAUTION TO AVOID PERSONAL INJURY OR PROPERTY DAMAGE THE FOL LOWING SAFETY INSTRUCTIONS APPLY WHENEVER ACCESSING THE INSIDE OF THE...

Page 32: ...e entire unit not just to the server s To avoid risk of potential electric shock a proper safety ground must be implemented for the rack and each piece of equipment installed in it Elevated Operating...

Page 33: ...le Earthing Reliable earthing of rack mounted equip ment should be maintained Particular attention should be given to supply connections other than direct connections to the branch circuit e g use of...

Page 34: ...CAUTION DO NOT ATTEMPT TO DISASSEMBLE PUNCTURE OR OTHERWISE DAMAGE A BATTERY CAUTION CAREFULLY ROUTE CABLES AS DIRECTED TO MINIMIZE AIRFLOW BLOCKAGE AND COOLING PROBLEMS FOR PROPER COOLING AND AIRFLOW...

Page 35: ...ified and rated Laser Class I for Optical Transceiver product CAUTION TO AVOID RISK OF RADIATION EXPOSURE AND OR PERSONAL INJURY Do not open the enclosure of any laser peripheral or device Laser perip...

Page 36: ...Regulatory and Compliance Information Chapter 4...

Page 37: ...sting Marks USA Canada CE Mark Europe FCC Marking Class A USA This device complies with Part 15 of the FCC Rules Operation of this device is subject to the follow ing two conditions 1 This device may...

Page 38: ...2 GOST R Marking Russia ICES Canada This Class A digital appara tus complies with Canadian ICES 003 Cet appareil num rique de la classe A est conforme la norme NMB 003 du Can ada Recycling Pack age Ma...

Page 39: ...d on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and the...

Page 40: ...mmission KCC Class A State ment Regulated Specified Components To maintain the UL listing and compliance to other regulatory certifications and or declarations the following regulated com ponents must...

Page 41: ...m in place to restrict the use of banned substances in accordance with the European Directive 2002 95 EC Compliance is based on declaration that materials banned in the RoHS Directive are either 1 bel...

Reviews: