SERVICE & MAINTENANCE 

Summary of Contents for EcoBoiler BK068

Page 1: ...PLEASE RETAIN THIS GUIDE FOR FUTURE REFERENCE Operating Installation Manual Stratford EcoBoiler Stove BK068 EN 13240 2001 Rev 03 June 2008 Part No AFS1362 08...

Page 2: ...h is why we are so confident in the reliability of our products Should you have any questions about our Stratford Stoves that are not covered buy our manual set please contact the Stratford dealer in...

Page 3: ...ing positions 21 Water connections 22 Hot water system check list 23 Final installation check list 24 Page No SERVICE MAINTENANCE Annual Maintenance 25 Cleaning 25 Chimney Sweeping 25 Door Glass Outer...

Page 4: ...Y HETAS IF IN DOUBT CONTACT HETAS LIMITED TELEPHONE NUMBER 0845 634 5626 www hetas co uk THIS STOVE MUST NOT BE CONNECTED TO A SHARED FLUE SYSTEM TO ALL USERS PETROLEUM COKE SOME OF WHOSE BRAND NAMES...

Page 5: ...t possible THE PRINCILE OF THE STOVE Your Stratford stove is built to the highest standard of craftsmanship using the best materials and the most modern equipment available It is a highly efficient an...

Page 6: ...0 Stratford SEB 40 1 Fuel retainer 1 1 1 1 2 Grate bars 9 11 13 13 3 Lower FEDS cover 1 1 1 1 4 Flue spigot 1 5 1 5 1 6 1 6 5 Hot plate 1 5 1 5 1 6 1 6 6 Ash pan 1 1 1 1 7 Operating tool 1 1 1 1 9 Fir...

Page 7: ...rise of the following parts Stratford EcoBoiler Stove Part Description Visual Aid not to scale Slab top Rolled top Raised top 1 Main canopy component 1 1 1 2 Top hot plate cover 1 1 0 3 Rear flue Top...

Page 8: ...p mm 3 Kg TBA TBA 686 609 TBA TBA TBA TBA Height Weight Rolled top mm 3 Kg TBA TBA 681 626 TBA TBA TBA TBA Height Weight Raised top mm 3 Kg TBA TBA 777 625 TBA TBA TBA TBA Mean Flue Gas Temperature C...

Page 9: ...lled on a floor with adequate load bearing capacity If the existing construction does not meet this prerequisite suitable measures e g load distributing plate should be taken to achieve it Ideally the...

Page 10: ...low section of the comb See Fig 1 The upper bar is fitted in a similar manner but with the end marked L inserted in the rear channel and the end marked H seated on the high section of the comb See Fig...

Page 11: ...inner section of the FEDS is welded in place during manufacture and requires nothing more than the removal of any residues produced by the flue gases that may have built up on the surfaces The Outer...

Page 12: ...ate as shown The Slab top and Roll top canopy blanking plates drop in place and requires no fixings see fig C The raised top canopy is held in place by 2 off M6 wing nuts located on the under side of...

Page 13: ...mney can then be installed For Top flue exit using the Raised canopy fit the top flue spigot and connecting flue pipe first Then fit the Raised canopy as shown in fig D on page 12 The Top flue fillet...

Page 14: ...pendent on four main factors Flue gas temperature Flue height Flue size Flue terminal The stove must be connected to a suitable and efficient flue that provides a good up draught to safely take the pr...

Page 15: ...espect of providing a notice plate giving details on the chimney flue lining hearth and fireplace installation Approved Docu ment J of the building regulations for England and Wales is available from...

Page 16: ...o circumstances should this appliance be connected to a shared flue system that serves any other heating appliance Typical Rear Flue Outlet As Per BS 8303 1 Stratford EcoBoiler Stove Minimum 150mm 6 D...

Page 17: ...03 1 Typical Metal Insulation Chimney System To be installed to the chimney manufacturers instructions in compliance with Building Regulations and BS7566 Pts 1 to 4 17 PLAN VIEW OF REGISTER PLATE AND...

Page 18: ...facilitate draining and flushing Warning If a pipe stat is not fitted to control the radiator circulation pump then cold water corrosion can occur FAILURE TO COMPLY WITH THESE REQUIREMENTS WILL INVALI...

Page 19: ...ic Hot water System Using Four Boiler Tapings Central Heating Without Domestic Hot water System Using Four Boiler Tapings Note Diagrammatic representation only Design and calculations for individual s...

Page 20: ...c Hot water System Using Three Boiler Tapings Central Heating Without Domestic Hot water System Using Three Boiler Tapings Note Diagrammatic representation only Design and calculations for individual...

Page 21: ...Stratford EcoBoiler Stove 21 INSTALLATION Boiler Tapping Positions Dimensions mm SEB15 SEB20 SEB30 SEB40 A TBA 384 TBA TBA B TBA 366 TBA TBA C TBA 275 TBA TBA D TBA 475 TBA TBA Return Tapings Output...

Page 22: ...of any radiator installed as a Heat Leak should not be less than 10 of the rated output of the appliance to which it is connected The radiator should not be fitted with a control valve as it should n...

Page 23: ...ensure there are no air locks HOT WATER SYSTEMS Is boiler cross flowed YES NO Are the pipes correctly sized YES NO What is the calculated output required to heat the system Is a heat leak fitted YES...

Page 24: ...title Profession Capacity Telephone No Address Postcode Signed Date Registered member of e g CORGI OFTEC HETAS NACE NACS 7 Hearth Form of construction new or existing 8 Inspection and testing after co...

Page 25: ...luding the outlet at least twice a year per burning season It is important that the flue ways flue pipe and chimney be cleaned prior to lighting the fire af ter a prolonged shut down period For remova...

Page 26: ...ntrol knob fully clockwise as viewed with the damper shaft to your left until you reach the end of possible travel Place the thermostat on a flat surface with the base of the mechanism body on a small...

Page 27: ...the door aperture or catch This is quite normal and due to the settling of the casting The door can be re aligned using the following pro cedure When the stove is cold open the fire door so that it is...

Page 28: ...onto a flat surface with the rear face upwards Carefully remove the old rope gasket and old adhesive Take note of the layout of the rope seal Ensure no traces of the old adhesive or rust flaky paint...

Page 29: ...esive backing on the rope as you go start at the bottom of the window centrally Push the adhesive side of the rope into the grove on the rear of the door casting gradually work your way round until th...

Page 30: ...EFT LANDING CAVITY The build up of ash within the inner left landing cavity may take a considerable time to become evident However if left unchecked it may build up to such an extent that it could spi...

Page 31: ...stove that are not covered in this manual please contact your Arada dealer Please keep all repair receipts safely Please ensure you have this manual available when an engineer visits so they can comp...

Page 32: ...ob located at the bottom front left hand side of the stove The temperature of the water in the boiler jacket is transmitted buy the sensor phial located on the upper face of the rear boiler jacket out...

Page 33: ...ment of the air wash inlet position when the stove is alight and or hot and for emptying the ash pan See Fig 18 RIDDLING Use the operating tool to set the grate bars in the correct position for burnin...

Page 34: ...Prior to lighting the fire for the first time check with the installer that Installation and all building work is complete The chimney is sound and has been swept and is free from obstruction Adequate...

Page 35: ...ing Periods The appliance will burn for long periods at a re duced output rate provided Sufficient fuel is placed in the firebox The controls are set correctly Excessive draught is not present in the...

Page 36: ...HETAS registered engineer See page 15 for details ASH REMOVAL The appliance will require ash to be removed periodically ash may be removed with a small metal shovel whilst the fire is still alight by...

Page 37: ...EB 30 Stratford SEB 40 Stand TBA SEB20 STAND TBA TBA Gothic Tracery TBA SEB20 TRACEG TBA TBA Lattice Tracery TBA SEB20 TRACEL TBA TBA Raised Canopy TBA SEB20 CANOPY TBA TBA Slab Canopy TBA SEB20 SLAB...

Page 38: ...Retainer TBA AFS1378 TBA TBA FEDS Lower Plate TBA AFS1334 TBA TBA Grate Bar TBA AFS001 TBA TBA Hot Plate TBA AFS010 TBA TBA Operating Tool AFS008 AFS008 AFS008 AFS008 Ashpan TBA AFS1337 TBA TBA Flue...

Page 39: ...FS1365 AFS1365 Hinge Kit 2 x Hinges 6 x screws AFS1279 AFS1279 AFS1279 AFS1279 Fire Door Rope Kit Glue AFS1021 AFS1021 AFS1021 AFS1021 Door Assembly TBA AFS1384 TBA TBA Fire Door Locking Assembly AFS1...

Page 40: ...2 TBA TBA Insulation Panel TBA AFS1355 TBA TBA Operating and Instruction Manual AFS1362 AFS1362 AFS1362 AFS1362 Thermostat Access Cover AFS1321 AFS1321 AFS1321 AFS1321 Mitten AFS1285 AFS1285 AFS1285 A...

Page 41: ...tc Nor can the guarantee be extended to deterioration of parts through fair wear and tear Firebox linings grate bars fuel retainer FED throat plate gasket material and door glass are therefore not cov...

Page 42: ...Stratford EcoBoiler Stove ADDITIONAL NOTES 42...

Page 43: ...Stratford EcoBoiler Stove 43 ADDITIONAL NOTES...

Page 44: ...rate Bars Rear Fire Bed Supports FEDS Cover Air Wash Door Catch Ash Pan Operating Tool Thermostat Mitten Operating Installation Manual Assembled By Checked by Date of Purchase Name and Address of Supp...