Stratco Outback Flat Attached Installation Manual Download Page 6

FASCIA BEAM TO RAFTER CONNECTION

Lift the front fascia beam and slide the rafter bracket onto 
the end of the rafter beam so that the end of the rafter is 
butted up against the back of the bracket. Support the front 
fascia beam on construction props allowing for a 1 in 500 
fall. Fasten the rafter beams either side with two 12x20 self 
drilling screws (Figure 3.3).

IN-LINE BEAM CONNECTION

To butt join beams together an in-line beam connector is used. 
The connector is placed so the join is in-line with the centre 
of a column. On the ground, slide the connector into the end 
of the beam. Fix using four 12x20 hex head screws either side. 
Push the exposed half of the in-line connector into the other 
beam until both beams meet flush and fasten as previously 
described (Figure 3.4). 

FULL MOMENT BEAM CONNECTION

If the beams must be joined at a location other than over 
a post, a full moment beam connection is required (Figure 
3.5). Slide the connector halfway inside the beam while it 
is still on the ground. Fix the connector in place using six 
12x20 self drilling screws; two either side of the beam and 
two on top of the beam. Push the exposed half of the in-line 
connector into the other beam until both beams meet flush 
and fasten using six 12x20 self drilling screws.

INTERMEDIATE BEAMS AND PURLINS

Intermediate beams and purlins may be fitted at this stage 
or following installation of the columns. Work progressively 
from the first end of the unit. Locate the rafter brackets and 
suspension brackets in the correct positions and fasten as 
previously described. Lift the first intermediate rafter into 
place and support on adjustable construction props (Figure 
3.6). Secure all connections using two 12x20 hex head screws 
either side of each bracket. Continue this process along the 
Outback unit until the final end rafter beam is fixed in place.

FRAMEWORK CHECK

Check that the basic framework is square by ensuring the 
diagonal measurements are the same. Recheck the falls are 
correct for the roof and gutter (Figure 3.7).

STRATCO OUTBACK

®

 FLAT ATTACHED INSTALLATION GUIDE

First end fascia beam

Front fascia beam

Intermediate beam

Wall bracket or

suspension bracket

Adjustable 

construction

props

Purlin

FIGURE 3.6

Two 12x20 hex head
screws either side

Beam bracket fits inside

incoming beam

Front Fascia Beam

End Fascia Beam

FIGURE 3.3

In-line beam 

connector

12x20 hex head 

screws

Centre of column is

in line with join.

FIGURE 3.4

12x20 Self drilling
screws through the top

12x20 Self drilling
screws (either side)

38x25x1.6 RHS

welded to SHS

65x2.5 SHS

FIGURE 3.5

FIGURE 3.7

A

B

A

B

Diagonal measurement

Fall

Fall

Fall toward the 
downpipe position

Adjustable 
construction prop

Summary of Contents for Outback Flat Attached

Page 1: ...of the components Mark out the overall area of your verandah patio or carport and ensure that it is free from obstructions Beam to wall connections can cause diffculty if they coincide with door and window openings so avoid these in your design Ensure there is reasonable access for materials and working space and consider the disposal of run o water Check the column and beam positions on the groun...

Page 2: ...S Connector Inline SHS Connector Post Beam Bracket Right Hand SHS Connector Downpipe Post Cap Downpipe Outlet Beam End Cap COMPONENTS Suspension Bracket 68 Bolted Footing Plate SHS Footing Plate Downpipe Bracket 150 In Line Beam Connector PVC Nitrile External Internal Gutter Mitres Full Moment Beam Connector Beam Filler Outback RoofliteTM Universal Deck Strap Notched Beam Filler ...

Page 3: ...COMPONENT DIAGRAM End Fascia Beam Front Fascia Beam ...

Page 4: ...he BIP foam into the back channel to act as a weather seal when the roof sheets are pressed into it STEEL HOUSE FRAME ATTACHMENT When fixing the back channel to the steel fascia on a steel framed house the roofing above each rafter must be removed to allow enough room to install the rafter strengthening brackets Attach angle brackets to 75x25x1 6mm RHS reinforcement using 12x20 self drilling screw...

Page 5: ...djust the construction prop to allow for the required deck fall minimum of one degree or one and a half degrees for deck spans over 4000mm Fasten the end fascia beam to the bracket using two 12x20 hex head screws either side in the holes provided Figure 3 0 BRACKET AND FILLER CONNECTIONS Measure the front fascia beam Mark where the end fascia beams intermediate beams if required and columns meet C...

Page 6: ...ix 12x20 self drilling screws INTERMEDIATE BEAMS AND PURLINS Intermediate beams and purlins may be fitted at this stage or following installation of the columns Work progressively from the first end of the unit Locate the rafter brackets and suspension brackets in the correct positions and fasten as previously described Lift the first intermediate rafter into place and support on adjustable constr...

Page 7: ...p of the upstand with screws being a minimum 30mm apart Figure 5 0 Slide the top of the column over the post bracket and align the column and footing bracket Note It may be necessary to lift the fascia beam slightly to slide the column over the post bracket The unfluted faces of the column should be aligned with each face of the post to beam bracket Fasten using two 12x20 hex head screws either si...

Page 8: ...ost bracket and align the column and footing bracket if applicable It may be necessary to lift the fascia beam to slide the column over the post bracket The un fluted faces of the column should be aligned with each face of the post to beam bracket Fasten with two 12x20 hex head screws either side Figure 5 2 Post caps are used to cover the screw heads press firmly into position silicone can be used...

Page 9: ...ite is different on each side and therefore must align with the correct connection on the deck Figure 7 0 Ensure the lower tab of the Rooflite touches the Outback deck at the points shown Figure 7 0 and all sheeting is pushed firmly into the back channel 9mm holes must be pre drilled through the Rooflite at all of the fastener locations prior to fixing to allow for thermal expansion The Rooflite i...

Page 10: ...n and mark and cut a 75mm diameter hole in the base of the gutter near the back edge Insert the downpipe outlet from the inside of the gutter and waterproof with silicone Figure 9 2 CAPPING BEAM CAPS To prevent moisture from entering the beams and for aesthetics any beams with exposed ends require end caps to be fitted Align the end cap and push into the exposed beam end Figure 8 0 POST CAPS If Ou...

Page 11: ...s into the mitre and the stop end slides up behind the back channel Fix the gutter in position as previously described and waterproof with silicone DOWNPIPES Before attaching the downpipes rivet the downpipe brackets to the column Slide the downpipe over the downpipe outlet and rivet into position Rivet the downpipe to the brackets Weatherproof all the fasteners with silicone FINAL FIXING FIXING I...

Page 12: ...laced in close contact with sources of pollution or environmental factors that could affect the life of the steel Refer to the Selection Use and Maintenance brochure for more information SHS COLUMN If using SHS columns the footing plate is to be fixed to the concrete slab with four M12x75 masonry anchors or screw bolts Figure 10 2 SHS REINFORCED OUTBACK COLUMN Reinforced Outback Columns are to be ...

Page 13: ... 135 190 0mm 50 60 70 80 90 40 30 20 10 100mm FOLD FOLD 20mm 58mm 80mm EDGE 160 EXTERNAL MITRE FLAT PATTERN TEMPLATE CUT OUT TEMPLATE FOR MARKING UP GUTTERS FLIP TEMPLATE FOR LEFT RIGHT VARIATIONS ENSURE TEMPLATES ARE PRINTED AT ACTUAL SIZE EXTERNAL PAGE 1 ...

Page 14: ...GUTTER FRONT 45 55 35 FOLD FOLD FOLD FOLD 110mm 24mm EXTERNAL PAGE 2 ...

Page 15: ...STRATCO OUTBACK FLAT ATTACHED INSTALLATION GUIDE 45 45 45 45 FOLD FOLD FOLD 20mm 58mm 80mm INTERNAL PAGE 1 ...

Page 16: ...TEMPLATE CUT OUT TEMPLATE FOR MARKING UP GUTTERS FLIP TEMPLATE FOR LEFT RIGHT VARIATIONS ENSURE TEMPLATES ARE PRINTED AT ACTUAL SIZE GUTTER FRONT 45 170 125 55 0mm 50 60 70 80 90 40 30 20 10 100mm FOLD FOLD FOLD 110mm 24mm INTERNAL PAGE 2 ...

Page 17: ...m FOLD FOLD 20mm 58mm 80mm EDGE 160 135 EXTERNAL MITRE FLAT PATTERN TEMPLATE A CUT OUT TEMPLATE FOR MARKING UP GUTTERS FLIP TEMPLATE FOR LEFT RIGHT VARIATIONS ENSURE TEMPLATES ARE PRINTED AT ACTUAL SIZE PAIR BELOW TEMPLATE 135 EXTERNAL A WITH 135 EXTERNAL B SEE OVER 135 EXTERNAL PAGE 1 ...

Page 18: ...GUTTER FRONT FOLD FOLD FOLD FOLD 110mm 24mm 135 EXTERNAL PAGE 2 135 INTERNAL MITRE TAGS FEATURED ON ONE SIDE OF EACH JOIN 135 EXTERNAL MITRE 135 135 ...

Page 19: ...AL MITRE FLAT PATTERN TEMPLATE B WITH TAGS CUT OUT TEMPLATE FOR MARKING UP GUTTERS FLIP TEMPLATE FOR LEFT RIGHT VARIATIONS ENSURE TEMPLATES ARE PRINTED AT ACTUAL SIZE PAIR BELOW TEMPLATE 135 EXTERNAL B WITH 135 EXTERNAL A FOLD TAGS TO FEED INSIDE ADJOINING GUTTER RIVET MITRE SIDE A TO THE INTERNAL TAGS OF MITRE SIDE B ONCE NEATLY JOINED ...

Page 20: ...0mm 50 60 70 80 90 40 30 20 10 100mm FOLD FOLD 20mm 58mm 8 0 m m 135 EXTERNAL TAGS PAGE 2 135 INTERNAL MITRE TAGS FEATURED ON ONE SIDE OF EACH JOIN 135 EXTERNAL MITRE 135 135 ...

Page 21: ...STRATCO OUTBACK FLAT ATTACHED INSTALLATION GUIDE FOLD FOLD 20mm 58mm 80mm 135 INTERNAL PAGE 1 135 INTERNAL MITRE TAGS FEATURED ON ONE SIDE OF EACH JOIN 135 EXTERNAL MITRE 135 135 ...

Page 22: ... 110mm 24mm 135 INTERNAL PAGE 2 EDGE 160 135 INTERNAL MITRE FLAT PATTERN TEMPLATE A CUT OUT TEMPLATE FOR MARKING UP GUTTERS FLIP TEMPLATE FOR LEFT RIGHT VARIATIONS ENSURE TEMPLATES ARE PRINTED AT ACTUAL SIZE PAIR BELOW TEMPLATE 135 INTERNAL A WITH 135 INTERNAL B SEE OVER ...

Page 23: ...T ATTACHED INSTALLATION GUIDE GUTTER FRONT 0mm 50 60 70 80 90 40 30 20 10 100mm FOLD FOLD FOLD FOLD 110mm 24mm 135 INTERNAL TAGS PAGE 1 135 INTERNAL MITRE TAGS FEATURED ON ONE SIDE OF EACH JOIN 135 EXTERNAL MITRE 135 135 ...

Page 24: ...LIP TEMPLATE FOR LEFT RIGHT VARIATIONS ENSURE TEMPLATES ARE PRINTED AT ACTUAL SIZE PAIR BELOW TEMPLATE 135 INTERNAL B WITH 135 INTERNAL A FOLD TAGS TO FEED INSIDE ADJOINING GUTTER RIVET MITRE SIDE A TO THE INTERNAL TAGS OF MITRE SIDE B ONCE NEATLY JOINED FOLD FOLD 20mm 58mm 80mm 135 INTERNAL TAGS PAGE 2 ...

Reviews: