Disposing of the Filters
Page 10
© Copyright 2021 Stratasys. All rights reserved.
Replace the filters when the maintenance LED, shown in
, turns from green to red and
flashes, or when the system no longer removes fumes efficiently.
The printer software notifies you when to replace the combined filter.
The recommended replacement schedule is as follows:
• Combined filter: every 350 printing hours or 6 months, or sooner if the filter replacement
indicator turns red and flashes.
Figure 5: Filter replacement indicator on control panel
To replace the combined filter:
1. Turn off the system power switch.
2. Open the clips on the sides of the system and remove the cover.
3. Lift the filter out of the system.
4. Insert the new filter into position.
5. Replace the cover, and fasten the clips.
Disposing of the Filters
The combined filter is manufactured from non-toxic materials. Filters are not re-usable. The
method of disposal of the used filters depends on the material deposited on them.
It is the customer's responsibility to verify that the disposal of filters complies with all local
and/or industrial regulations.
If the fan speed is higher than recommended, the filter will become clogged earlier
than expected. The fan speed level should not be set below level 2.
It is recommend to place the used filters in a sealed bag before discarding.
Do not activate the system without a filter.