UNINTERRUPTIBLE POWER SUPPLY (UPS) 

USE AND INSTALLATION

The intent of the Uninterruptible Power Supply (UPS) shutdown feature on Fortus systems is to prevent required 
maintenance and/or system damage by safely shutting the system down in the event of an uncontrolled loss of 
power. Whether an in-process build of a part will complete successfully is dependent on the battery life of the 
selected UPS and the duration of the power outage.

The user should select a UPS with the following specifications:

• 

Runtime minimum of 15 minutes at 1000W or 2000VA output (run times >15 minutes may be 

appropriate based on the typical duration of power outages at the site).

• 

Runtime minimum 8 minutes after low battery warning tripped.

• 

Peak output (minimum) of 1500W.

• 

Dry contact (voltage free) interface for “On battery” and “Low battery” conditions.

• 

Dry contact interface capable of carrying at least 100mA at 12VDC.

GENERAL INFORMATION

Refer to the UPS and I/O Module (if used)

 

Installation and Operation Guides for instructions on installing the I/O 

module (if used) into the UPS unit as well as for connecting AC power to the UPS and Fortus system. While 
connecting the Fortus system power to the UPS will provide some protection against power outages, the Fortus 
system will shut down safely when “on battery” and “low battery” conditions are detected. Follow the Electrical 
Interface Connection information below.

1. 

Configure Normally Open dry contact relay I/Os of UPS as shown in 

Figure 1

 

(Wired-And configuration).

2. 

Build an appropriate length of UPS to Fortus system cable. See 

Figure 2

 for pin out.

3. 

Connect the cable from the UPS unit’s connector to the UPS (9-pin DSub) connector on the rear 
of the Fortus system.

4. 

Follow the instructions in the UPS Installation and Operation Guide to set the “Low Battery 
Warning Level” to 8 minutes.

Note: 

Make certain to install the jackscrews that hold the cable connectors to their 

respective mates (do not over-tighten)

Note: 

The default low battery warning level value may not provide adequate time to 

ensure the Fortus system can shut down safely.

Summary of Contents for Fortus 250mc

Page 1: ...Part No 400713 0001_REV_A Fortus 250mc SITE PREPARATION GUIDE...

Page 2: ...th Stratasys per software copyright No part of this document may be photocopied reproduced or translated into another language without the prior written consent of Stratasys Inc All drawings and infor...

Page 3: ...tion 3 WORKSTATION REQUIREMENTS 3 ELECTRICAL REQUIREMENTS 3 AC Power Requirements 3 LAN REQUIREMENTS 3 UNINTERRUPTIBLE POWER SUPPLY UPS 4 USE AND INSTALLATION 4 GENERAL INFORMATION 4 Parts List Cable...

Page 4: ...the ground lead Know the location of equipment branch circuit interrupters or circuit breakers and how to turn them on and off in case of emergency Know the location of fire extinguishers and how to...

Page 5: ...1 model 1 support User Interface with Display Panel and Keypad HOW TO USE THIS GUIDE This guide provides information for selecting an appropriate location for the Fortus 250mc Information of particula...

Page 6: ...Air quality conditions with excessive solid particulates conductive or non conductive may result in system damage Air quality conditions in which airborne oils are allowed to accumulate on or within...

Page 7: ...A LAN connection is required for communication and file transfer functions The LAN connection is a 100 base T Ethernet protocol RJ45 connector One CAT5 10 100 base T cable is supplied with the printe...

Page 8: ...nd I O Module if used Installation and Operation Guides for instructions on installing the I O module if used into the UPS unit as well as for connecting AC power to the UPS and Fortus system While co...

Page 9: ...sg Plug 9Pos AMP 205204 9 2 2 Pin Male 24 20 AWG AMP 1 66506 0 3 1 Shell Size 1 9 Pin w Grommets AMP 748677 1 4 2 Jackscrew Pair 4 40 Knurled AMP 747784 3 5 XX x Cable 2 Conductor 22 AWG ALPHA 1172C o...

Page 10: ...6 Figure 2 UPS Cable Diagram...

Page 11: ...e system should be 2 8 m 104 in high 2 2 m 86 in wide and 1 9 m 76 in deep For detailed unpacking and setup instructions refer to Chapter 3 of the Fortus 250mc User Guide SITE PREPARATION CHECKLIST EL...

Page 12: ...aterials and applications call 888 480 3548 or visit www stratasys com DOCUMENTATION FEEDBACK Customers resellers and Stratasys employees are encouraged to send comments about our documentation and tr...

Reviews: