5.1
Electrical Connection
The AdvanceCut45 is designed to operate on a 15A 240V AC power supply.
5.2
Extension Leads
If an extension cord must be used, it should be minimum cable core size 2.0mm
2
for length of up to
10m, or minimum 2.5mm
2
for lengths over 10m.
Using extension leads of over 100m
is not recommended.
5.3
Generator Use
This machine is designed with generator use in mind and incorporates wide voltage tolerance and
intelligent voltage sensing technology to provide maximum protection from power fluctuations that
can occur with motor generators.
5.3.1
Generator Size
Generator size should be not less than 8kva. A 10kVa generator will not provide enough power to
enable full output and duty cycle of this plasma cutter. However, it should provide sufficient power
for lighter cutting and short runs.
To enable full output and duty cycle of this plasma cutter a recommended generator size is
minimum 10kVa.
5.3.2
Generator Quality & Warranty Limitations
Avoid using poor, low quality generators as these have the greatest risk of power spikes etc. A
suitable quality generator should have a THD (total harmonic distortion) rating of no more than 6%.
Most reputable generator suppliers will be able to specify the THD ratings on their product.
Any damage caused by poor quality generator power supply or incorrect use is not covered under
warranty.
5.3.3
3 Golden Rules of Generator use
When running an inverter plasma cutter off a generator there are 3 VERY IMPORTANT Golden Rules
that MUST be followed:
1.
Do
NOT
plug plasma cutter into generator until
AFTER
generator has been started up and is
running smoothly
2.
UNPLUG
plasma cutter from generator
BEFORE
shutting generator down/turning generator
off
3.
NEVER
let your generator run out of fuel whilst the plasma cutter is plugged in.
Following these Golden Rules will significantly reduce the risk of any damage resulting from
generator power supply.