background image

Operating instruction Z7520 Compact-temperature-controller

I

  Temperaturregelgeräte

17

STRACK NORMA GmbH & Co. KG · Königsberger Str. 11 · D-58511 Lüdenscheid · Tel +49 2351 8701-0 · www.strack.de

08.2018

Operations manual 

         Z7520

 

 

 

STRACK NORMA GmbH & Co. KG 

     19  

 

Type of PIDcaracteristic (Control Mode) 

 

for output 1 

 

 

 

 

 

    

 

SELF = Selftuning 

 

 

At = Autotuning 

 

       

 

Selftuning :  Slow, no overshoot, less 

 

 

 

 

 

   precise 

 

 

 

Autotuning : Quick, overshoot accepted, 

 

 

 

 

 

   more precision 

 

 

Heat / Cool 

 

(type Heat Cool) for 

Output 1 

and  

 

 

 

 

 

 

 

2 (option) 

 

 

 

 

     

Output 1

      

Output 2 (Opt.)

 

 

 

 

Heat  

 

Cool 

 

 

 

 

Cool  

 

Heat 

 

 

 

Cycle time output 1 

 

(Cycle time 1) 

 

0  60 sec. 

 

 

 

 

 

 

 

 

 

 

Proportional band output 1 

 

(Prop.band 1 or Autotuning P.band 1) 

 

 

 

Depending on type of PID

 

caracteristic (see above)

 

For Selftuning 0  100 °C

Summary of Contents for Z7520

Page 1: ...MULTIZONE TEMPERATUR CONTROLLER Z7520 OPERATING INSTRUCTION...

Page 2: ...ng the instructions given in this manual Warranty period is 2 years and includes all malfunctions clearly caused by material production or design failures Repair or replacement in this case are free o...

Page 3: ...desired temperature 5 4 Configuration level 1 Working level Shows powersetting alarm values autotuning 5 5 Configuration level 2 Program level Control mode adaptation to controlled system heat cool s...

Page 4: ...temperature controller with the following features Integrated power supply for 1 or 2 zones Usable for heating or cooling PID caracteristic 2 point controller or manual constant powersetting Auto adap...

Page 5: ...erior with debris liquids or sprays Risk of short circuit fire or electric shock 6 Before dismantling the controller insert from the frontpanel remove the blocking screw upper side of the carter red p...

Page 6: ...be send back to our factory Attempted self repair causes immediate termination of the warranty period If spare parts are required only parts recommended by the supplier must be used The use of other...

Page 7: ...lay 7 segment LED display 8mm green actual value and red set point signal LEDs red for output and alarm Soft start Softstart time min and powersetting 0M100 programmable Heating and TC connection 6pol...

Page 8: ...power cable from heat and mechanical stress Do not place the device on hot surfaces 4 2 Connection of the power supply This device must only be operated at the voltage indicated on the name plate Ple...

Page 9: ...iring for 1 zone NR2007 1 for 2 zones NR2007 2 following NR Norm NR6 following NR Norm NR10 Other pin assignment schemes on request see Annex page 29 of this operations manual 5 4 Alarm output For eve...

Page 10: ...uction Z7520 Compact temperature controller I Temperaturregelger te 10 STRACK NORMA GmbH Co KG K nigsberger Str 11 D 58511 L denscheid Tel 49 2351 8701 0 www strack de 08 2018 Front side Z 7520 2 Back...

Page 11: ...OFF 0 Herewith all poles are disconnected from the mains voltage The main switch can be locked following EN81 80 Before working on the device itself or on a tool connected to it the switch must be loc...

Page 12: ...51 8701 0 www strack de 08 2018 Operations manual Z7520 14 5 2 Display and keys PV Normal operation ACTUAL temperature SV Normal operation SETPOINT temperature Both available 4 digits or 3 digits with...

Page 13: ...ameter DOWN key Decreases the value of the selected parameter Press Down key for 2 sec Controller OFF ON Press UP and DOWN key simultaneously for 2 sec Start Stop Autotuning ENTER key Selects the para...

Page 14: ...p of Page in this level Press LEVEL key 2 sec within the selected menu level back to normal operation 5 3 Adjustment of the SETPOINT temperature Adjusting the SETPOINT temperature can be done without...

Page 15: ...the menu level with the Level key Display Select the parameter with the UP or DOWN keys Display actual power setting 0 100 outPut Percentage 1 Alarm 1 signal contact ALarm low value Process Low temper...

Page 16: ...0 18 Autotuning Start Autotuning No Stop Autotuning Back to Top of Page 1 parameter 5 5 Configuration level 2 Program level Select the menu level with the Level key Display Select the parameter with t...

Page 17: ...ype of PID caracteristic Control Mode for output 1 SELF Selftuning At Autotuning Selftuning Slow no overshoot less precise Autotuning Quick overshoot accepted more precision Heat Cool type Heat Cool f...

Page 18: ...2018 Operations manual Z7520 20 Integral time output 1 int time 1 or Autotuning i time 1 Depends on type of PID caracteristic see above 0 250 0 1 sec Differential time output 1 diff time 1 or Autotuni...

Page 19: ...erer GK Invertierter Oberer GK Invertierter Unt Ob GK Absolutwert Invertierter Absolutwert Einstellung Hysterese Alarm 1 5 6 Configuration level 3 Program level Bedienungsanleitung Z7520 STRACK NORMA...

Page 20: ...22 Inverted lower limit con Inverted upper limit con Inverted low hi lim c Absolute value Inverted absolute value Hysteresis Alarm 1 0 10 C F Analogue output Option Lower limit in 0 1 mA Analogue out...

Page 21: ...elect the menu level with the Level key Display Select the parameter with the UP or DOWN keys Key lock 0000 0044 Last digit levels up to PLE permitted Tens digit levels up to PLE permitted Type thermo...

Page 22: ...tion of one solder bridge on the main circuit board this adjustment is done at the factory To change this setting after delivery the solder bridge needs to be modified by a qualified technician Bedien...

Page 23: ...K nigsberger Str 11 D 58511 L denscheid Tel 49 2351 8701 0 www strack de 08 2018 Operations manual Z7520 STRACK NORMA GmbH Co KG 27 Temperature unit C or F Offset thermocouple input 99 99 C F Limit p...

Page 24: ...lger te 24 STRACK NORMA GmbH Co KG K nigsberger Str 11 D 58511 L denscheid Tel 49 2351 8701 0 www strack de 08 2018 Operations manual Z7520 STRACK NORMA GmbH Co KG 29 7 Annex Customized connector pin...

Page 25: ...08 2018 STRACK NORMA GmbH Co KG K nigsberger Str 11 D 58511 L denscheid Postfach 16 29 D 58466 L denscheid Tel 49 2351 8701 0 Fax 49 2351 8701 100 Mail info strack de Web www strack de...

Reviews: