THE USER INTERFACE

USE OF THE KEYS
The keys of the instrument permit both
the utilisation of the menu and the direct
activation of a function.

USE OF THE MENUS
ACCESS TO THE MAIN MENU
The programming of the instrument is
organised by menu (see Fig. 2, Menu flow-
chart), which can be accessed by keeping
the key 

pressed down for the time set 

by H02 parameter. 

NAVIGATION OF THE MENUS
In order to access the contents of each
folder, just press the key 

once.

If called for, a password will be required.
There are two different passwords. The
first password (PA1) is for access to the
parameters in the PL1 folder. The second
password (PA2) is for access to the para-
meters in the PL2 folder. (see Fig. 2, Menu
flowchart). 
At this point in the proceedings it is possi-
ble to scroll through the contents of each
folder & amend them .
If you do not use the keyboard or hit the

key within 15 seconds, the last value

displayed on the screen is confirmed

and you return to the previous screen.

DESCRIPTION OF FOLDERS

PL1 = user parameters (level 1)
This folders contains the parameters
required by the end user in order to make
any minimum amendments to the pro-
gramming parameters (see Table 6 and
Table 7).

PL2 = machine parameters (level 2)
This folders contains the parameters
required by the  manufacturer and the
assembler for the optimum configuration
of the controlling machine (see Table 6
and Table 7).

St = machine status
In this folder the status of the input 2  can
be viewed; (see Table 4).

RAPID ACTIVATION

Certain specific functions (Setpoint,
defrost) are associated with keys on the
frontlet (see Table 2, Keys and functions
set directly).

DISPLAY AND DEFINITION OF THE SET-
POINT VALUE
In order to view the Setpoint value, keep
the key 

pressed down for the time set 

by Pa H02 parameter.

The Setpoint value will appear on the dis-
play and the temperature gauge icon will
begin to flash. In order to vary the
Setpoint value operate, within 15 seconds,
on the keys 

and 

If the parameter LOC = y is not possible to
modify the Setpoint.

MANUAL ACTIVATION OF THE DEFROST
CYCLE
Manual activation of the defrost cycle is
achieved by keeping the key 

pressed

down for “Pa H02” seconds. 

KEYPAD LOCK
The instrument anticipates, by means of
appropriately programming the “Loc”
parameter (see Table 6, “Miscellaneous”
parameters), the possibility of disabling the
functioning of the keypad.
In the event the keypad is locked, the user
can always access the programming MENU
by pressing the key 

If there is not available to start defrosting,
the defrost LED will blink 5 times

PARAMETERS

The parameters can be viewed in two dif-
ferent tables: the first (see Table 6)
describes the function of the parameter,
while the second (see Table 7) lists the
characteristics of each parameter.

DIAGNOSTICS

The alarm icon indicates an alarm condi-
tion. Breakdowns are indicated on the
screen (see Table 5). 
When an alarm status occurs, it is possible
to silence the buzzer and/or relay config-
ured as an alarm, by pressing any key.
The buzzer is optional and is present on
the EWDB 111 B model.

EWDB 111

electronic controller for refrigerating units

KEY

DESCRIPTION

UP key

DOWN key

ESC key

ENTER key

FUNCTION

Scrolls through the menu
items
Increases the values
Scrolls through the menu
items
Decreases the values

Returns to the previous
level

Accesses the menus
Confirms the commands

Table 1

Keys and menu

PARAMETER

Pb2
sensor 2

VALUE

sensor 2 value

Table 4

Machine status table

KEY

DESCRIPTION

UP

ESC

DOWN

ENTER

FUNCTION

Activates manual defrost
function

Accesses the setpoint

Accesses the program-
ming menu

Table 2

Keys and functions set directly

Fig. 1

Frontlet of instrument

ICON

INDICATION

alarm active

temperature
range (°F if
icon turn-off)

defrost active

compressor

DETAILS

Permanently lit up in the
event of an alarm, flash-
ing in the event of a
silenced alarm

Flashing in paramete
programming 

Permanently lit up in the
event of defrosting in
progress, flashing in the
event of manual defrost

Permanently lit up in the
event of compressor
valve working, flashing in
the event of delay in
activating 

Table 3

Icons

Summary of Contents for EWDB 111

Page 1: ...the keys and If the parameter LOC y is not possible to modify the Setpoint MANUAL ACTIVATION OF THE DEFROST CYCLE Manual activation of the defrost cycle is achieved by keeping the key pressed down for Pa H02 seconds KEYPAD LOCK The instrument anticipates by means of appropriately programming the Loc parameter see Table 6 Miscellaneous parameters the possibility of disabling the functioning of the ...

Page 2: ...rosting 0 interval between two defrost cycles in hours duration of defrost cycle in minutes 1 interval between two defrost cycles in minutes duration of defrost cycle in seconds Defrost interval reckoning mode 0 only the running time of the compressor is counted 1 the running time of the instrument is counted 2 defrosting takes place every time the compressor shuts down Delay in commencement of de...

Page 3: ... to its automatic operating fea tures as a 1 B type operated control type as a Class A device in relation to the cat egory and structure of the software USE NOT PERMITTED Any other use other than that permitted is de facto prohibited It should be noted that the relay contacts provided are of a practical type and there fore subject to fault Any protection devices required by product standards or di...

Page 4: ...tial High SEt Low SEt On time compressor OFF time compressor dealy On compressor dealy OFF compressor delay between interval Output delay at On defrost interval time defrost time unit defrost count type defrost Offset defrost Endurance time defrost at Power ON defrost reset interval Alarm fan differential Alarm temperature type High ALarm Low ALarm Power on Alarm Override defrost Alarm Override te...

Reviews: