EWDB 111
APPENDIX 1
Table 10
Complete parameters table
PARAMETER
SEt
diF
HSE
LSE
Ont
OFt
dOn
dOF
dbi
OdO
dit
dtU
dCt
dOH
dEt
dPO
dri
Afd
Att
HAL
LAL
PAO
dAO
tAO
AOP
LOC
PA1
PA2
ndt
CAL
LdL
HdL
dLc
dro
H02
H21
H23 (1)
reL
tAb
LEVEL
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
1
1
1
1
2
2
2
2
2
2
2
2
RANGE
LSE...HSE
0.3...30.0
LSE..302
-67...HSE
0...250
0...250
0...250
0...250
0...250
0...31
0...250
0/1
0/1/2
0...250
1...250
n/y
n/y
1.0...50.0
0/1
LAL..302
-67...HAL
0...10
0..999
0...250
0/1
n/y
0...255
0...255
n/y
-30...30
-67...302
-67..302
0/1/2
0/1
0…250
0…4
0…4
/
/
DEFAULT
0
2
50
-50
10
0
0
0
0
0
6
0
1
0
30
n
y
2
1
50
-50
2
60
0
1
n
0
0
n
0
-50
110
1
0
5
1
3
/
/
U.M.
°C/°F
°C/°F
°C/°F
°C/°F
min
min
sec
min
min
min
h
num
num
min
min/sec
flag
flag
°C/°F
num
°C/°F
°C/°F
h
min
min
num
flag
num
num
flag
°C/°F
°C/°F
°C/°F
num
num
sec
num
num
/
/
DESCRIPTION
SEtpoint
diFFerential
High SEt
Low SEt
On time compressor
OFF time compressor
dealy On compressor
dealy OFF compressor
delay between interval
Output delay at On
defrost interval time
defrost time unit
defrost count type
defrost Offset
defrost Endurance time
defrost at Power ON
defrost reset interval
Alarm fan differential
Alarm temperature type
High ALarm
Low ALarm
Power on Alarm Override
defrost Alarm Override
temperature Alarm Override
Alarm Output Polarity
keyboard LOCK
Password 1
Password 2
number display type
CALibration
Low display
High display
display Lock
display read-out
Tempo attivazione tasti
Configurabilità uscita digitale 1
Configurabilità uscita buzzer
reLease Firmware
tAble of parameters
PA2
PA1
folder PL2
St
PL2
PL1
Main Menu
ENTER Key
Tab. 4
folder PL2
folder PL1
folder PL1
Tab. 4
1 2 3
5 6 7 8
1 2 3
5 6 7 8
1 2 3 4 5
7 8
1 2 3 4 5
7 8
WIRING
1 - 2 - 3
4 - 5
5 - 6
7 - 8
compressor relay output
thermostatic sensor input
thermostatic sensor input
power supply
Fig. 2
Menù flowchart
Fig. 3
Schema di morsettiera