27
STRACK NORMA GmbH & Co. KG · Königsberger Str. 11 · D-58511 Lüdenscheid · Tel +49 2351 8701-0 · www.strack.de
08.2018
I
Operating instructions -- PowerMax
cam unit PMO
Power
Max
12. Modification of the system pressure of the gas springs
12.1 Discharging of the pressure at a gas spring
PowerMax cam unit SN5650-PMO-0065
—
SN5650-PMO-0260
1.
If necessary remove the closing plug.
2.
To loose the valve, use a 3 mm socket
wrench. Turn it to the right till the gas
escapes (1-2 turns).
3.
As soon as the gas spring is discharged,
turn the valve to the left till the initial
position is reached. The gas spring is
ready to be charged.
.