10
STRACK NORMA GmbH & Co. KG · Königsberger Str. 11 · D-58511 Lüdenscheid · Tel +49 2351 8701-0 · www.strack.de
08.2018
I
Operating instructions -- PowerMax
cam unit PMO
Power
Max
8. Production
During the production no particular precautionary measures have to be taken, which exceed the valid
operating safety regulations paragraph 3.
Advice:
Please secure that the
STRACK
cams especially the gas springs are not dipped
in fluid.
If you are using for example aggressive drawing oils during the production, make
a controlled drain for them (drainage borings, cutouts and so on), so that the
fluids are directed away from the gas springs.
Thereby seal damages are avoided.
Tip:
Control the nitrogen pressure of the gas springs in regular intervals, to detect
changes in the pressure level in time. During maintenance works you have to
consider a correct return of the cam slide.
Advice:
The cam units are equipped with low-maintenance slide elements out of bronze
with solid lubricant. In normal case lubrication is not necessary.
A lubrication may only be effected in case of need with the following lubricants:
PowerMax cam unit SN5650-PMO-0065
—
SN5650-PMO-0260
Company
Oils
Greases
AGIP
Potra ATF
Agip GR MU 2
BP
Autran DX II
Energrease
ESSO
ATF Suffix A
Nebula EP 2
ESSO
ATF - D
Beacon EP 2
OMV
ATF Serie
OMV signum CX 2
SHELL
Donax TM
Retinax LX
SHELL
Donax TF