background image

CAM UNIT 

SN5650-PMO-0065 — SN5650-PMO-0260

OPERATING INSTRUCTIONS

Power

Max

Summary of Contents for PowerMax SN5650-PMO-0065

Page 1: ...CAM UNIT SN5650 PMO 0065 SN5650 PMO 0260 OPERATING INSTRUCTIONS PowerMax...

Page 2: ...plate at cam units 0065 0260 only Premium 17 10 The Lock Out Systems 18 10 1 Lock Out System 5651 LOS 19 10 1 1 Mounting of the Lock Out System 5651 LOS 20 10 2 Lock Out System 5654 LOS 22 10 2 1 Inf...

Page 3: ...ed for all persons which are working with these cam units and which are responsible for the secure operating For reasons of the operating safety a copy of these operating instructions has to be left a...

Page 4: ...nitrogen gas spring is used incorrectly or not for the intended application menace Dangers for the health Dangers for the STRACK nitrogen gas springs and other property holdings of the operator Danger...

Page 5: ...transport company which has delivered the consignment Please compare the content of the consignment with the delivery note respectively the enclosed list of items see appendix Please also ascertain t...

Page 6: ...r number and filling pressure different at the diverse cam types determine the reset force which is available Please consider that all PowerMax cam units are the successful result of a long developmen...

Page 7: ...plates belong to these All cams can also be produced for the machining of high strength sheets contrary to the angles in five steps described in the catalogue in all intermediate angles according to...

Page 8: ...e x respectively the y axis Modifications of position which will be possible in future should be considered previously to choose a cam size which corresponds to the force To be able to guarantee an eq...

Page 9: ...ave to take care that punching wastes don t fall in or on the cam guidance Cam slide and guidances can seize Parts falling down can damage the guidances hereby possibly the running life of the cam red...

Page 10: ...e fluids are directed away from the gas springs Thereby seal damages are avoided Tip Control the nitrogen pressure of the gas springs in regular intervals to detect changes in the pressure level in ti...

Page 11: ...ndling 8 1 1 Handling with safety ring bolt adapter SN5655 PMO SRA The safety ring bolt adapter SRA facilitates the handling in many installation situations at the standard cams of the width 90 125 16...

Page 12: ...age hilfe assembling aid which is available for each cam unit size the threading of the sliding carriage is facilitated in the slide mount The safety ring bolt adapter SN5655 PMO SRA and the set of th...

Page 13: ...for cam units SN5653 M16 Montagehebel SN5653 M30 SN5650 PMO 0125 Assembly lever SN5650 PMU 0125 SN5653 M16 Montagehebel SN5653 M36 SN5650 PMO 0165 Assembly lever SN5650 PMU 0165 SN5650 PMO 0230 SN5650...

Page 14: ...her by means of the safety ring bolt SN1594 because of the fact that the different positions of the handling screwing thread facilitates the mounting of the cam slide in the slide retainer By changing...

Page 15: ...ing adhesive Z9093 Attention Don t remove the rails If this should be inevitable in a case of a crash the replacement strips have to be adjusted again To avoid confusions within a series the assembly...

Page 16: ...ing possible The high precision plate can be dismounted easily to be able to carry out further machining Step 1 Loose the fixing screws of the guide strips Remove the guide strips and put them aside p...

Page 17: ...ely necessary to clean the stop lug AN and the t nut guidance of both components in order that the bearing surface for the guide strips builds a level during the assembly The mounting plate is constru...

Page 18: ...instructions PowerMax cam unit PMO PowerMax PowerMax cam unit SN5650 PMO 0065 SN5650 PMO 0260 10 The Lock Out Systems 10 1 Lock Out System SN5651 LOS This lock out system can be used at mounted and di...

Page 19: ...1 SN5651 LOS SPS M8 x 120 1 SN5651 LOS DS 19 x 15 1 SN5651 PMO LOS 0125 SN5650 PMO 0125 SN5651 PMO LOS SPB 0125 1 SN5651 LOS SPS M8x120 1 SN5651 LOS DS 25 x 15 1 SN5651 PMO LOS 0165 SN5650 PMO 0165 S...

Page 20: ...10 1 1 Mounting of the Lock Out System SN5651 LOS To fasten the cam for the insertion of borings the fixation of the cam slide by means of a lock out system is necessary For this purpose please act as...

Page 21: ...Max cam unit SN5650 PMO 0065 SN5650 PMO 0260 SN5651 LOS DS SN5651 LOS SPB SPS picture 3 picture 4 3 Mounting of the clamping block SN5651 LOS SP Attention Moving the body without the clamping block ca...

Page 22: ...N5654 PMO LOS 0065 20 20 SN3500 M8 55 1 SN5651 LOS DS 19x15 1 SN5654 PMO LOS 0065 25 25 SN3500 M8 50 1 SN5651 LOS DS 19x15 1 SN5654 PMO LOS 0065 30 30 SN3500 M8 50 1 SN5651 LOS DS 19x15 1 SN5654 PMO L...

Page 23: ...N3500 M10 50 1 SN5651 LOS DS 25x15 1 SN5654 PMO LOS 0125 25 25 SN3500 M10 50 1 SN5651 LOS DS 25x15 1 SN5654 PMO LOS 0125 30 30 SN3500 M10 40 1 SN5651 LOS DS 25x15 1 SN5654 PMO LOS 0125 35 35 SN3500 M1...

Page 24: ...LOS 0230 65 65 SN3500 M12 55 1 SN5651 LOS DS 32x15 1 SN5654 PMO LOS 0230 70 70 SN3500 M12 55 1 SN5651 LOS DS 32x15 1 SN5654 PMO LOS 0230 75 75 SN3500 M12 50 1 SN5651 LOS DS 32x15 1 Type Screw Number...

Page 25: ...the cam body is screwed with the cam reception The special thing is that the clamping screws act under an angle on the corresponding bearing face That means the cam body is once pulled by the divided...

Page 26: ...closing plug have to be dismounted Attention after the unscrewing of the closing plug the cam slide is falling in its bottom end position The mounting is effected in the reverse order For this the ca...

Page 27: ...e of the gas springs 12 1 Discharging of the pressure at a gas spring PowerMax cam unit SN5650 PMO 0065 SN5650 PMO 0260 1 If necessary remove the closing plug 2 To loose the valve use a 3 mm socket wr...

Page 28: ...with the connector G1 8 in the gas spring Continue with step 3 For the gas springs with the connecting thread M6 A M8 2a Turn the adapter M6 A M8 on the connecting thread G1 8 2b Turn the charging equ...

Page 29: ...lve slowly in till the pressure escapes or till the desired pressure is indicated at the manometer Finally turn the adjusting screw of the discharge valve immediately back in the initial position You...

Page 30: ...the cam units Accident Prevention Regulation Please check the system pressure of the gas spring before restarting the tool If you have to increase the system pressure act as described in chapter 11 2...

Page 31: ...e prism of the cam slide After the installation of the driver on the cam slide push the active returns on the inserts of the driver and fix them by mov ing the adjusting wedges in the direction of the...

Page 32: ...de frottement 0 05 0 15 PV Wert PV value Valeur PV 2950 daN cm2 x m min Fl chenpressung max Surface pressure max Pression superficielle maximale 76 N mm2 Arbeitstemperatur Operating temperature Temp...

Page 33: ...ld exchange the low maintenance slide rails when they are damaged The hardened steel rails are adapted to the respective guide clearance of the cam and should not be exchanged in the normal case The l...

Page 34: ...ons PowerMax cam unit PMO PowerMax PowerMax cam unit SN5650 PMO 0065 SN5650 PMO 0260 Bronze with solid lubricant SNS Sinter metal Application test in the cam of a cutting tool Test tool Counter bearin...

Page 35: ...rMax cam unit PMO PowerMax 15 Appendix 15 1 Internet and CAD The company STRACK NORMA has created an online presence for the PowerMax cam elements which is tailored to the requirements of the construc...

Page 36: ...le leakage points All STRACK gas springs are supplied with a quality certificate COMPONENT CHARACTERISTICS Body Developed in one piece up to strokes of 125 mm In higher strokes they have a tubular con...

Page 37: ...s convenient to design with an optimal safety level It is therefore recommended to foresee a 10 stroke reserve picture 1 Working temperature Maximum working temperature is 80 C Higher temperatures can...

Page 38: ...pending on the type of work you wish to carry out Garantee and duration The guarantee that STRACK offers in gas springs is for one year as from the date of acquisition or the equi valente to a stem li...

Page 39: ...gas spring onto the tool in such a way it makes a free stem ejection possible The installation of a compressed gas spring is dangerous due to serious safety risks The gas spring is to work completely...

Page 40: ...643 724 804 884 965 1045 1126 1206 1206 150 SN2807 2100 150 2100 13 85 416 554 693 831 970 1108 1247 1385 1524 1662 1801 1939 2078 2078 150 SN2807 3000 150 3000 19 63 589 785 982 1178 1374 1570 1767...

Page 41: ...356 381 394 155 SN2809 600 155 600 3 80 114 152 190 228 266 304 342 380 418 456 494 532 570 589 155 SN2809 750 150 750 4 90 147 196 245 294 343 392 441 490 539 588 637 686 735 735 150 SN2809 1000 142...

Page 42: ...8 266 304 342 380 418 456 494 532 570 570 150 SN2830 1000 142 1000 7 06 212 282 353 424 494 565 635 706 777 847 918 988 1059 1059 150 SN2830 1500 148 1500 10 17 305 407 509 610 712 814 915 1017 1119 1...

Page 43: ...CK NORMA GmbH Co KG K nigsberger Str 11 D 58511 L denscheid Tel 49 2351 8701 0 www strack de 08 2018 I Operating instructions PowerMax cam unit PMO PowerMax PowerMax cam unit SN5650 PMO 0065 SN5650 PM...

Page 44: ...O 0260 16 Exploded view and item list 0 30 35 75 32 1 32 31 1 31 1 14 14 1 38 39 108 16 1 16 120 34 34 3 34 1 117 1 117 11 1 11 10 1 10 2 7 1 7 23 3 23 23 1 23 2 112 111 37 37 2 37 3 17 17 1 106 106 1...

Page 45: ...mbH Co KG K nigsberger Str 11 D 58511 L denscheid Tel 49 2351 8701 0 www strack de 08 2018 I Operating instructions PowerMax cam unit PMO PowerMax PowerMax cam unit SN5650 PMO 0065 SN5650 PMO 0260 Par...

Page 46: ...08 2018 STRACK NORMA GmbH Co KG K nigsberger Str 11 D 58511 L denscheid Postfach 16 29 D 58466 L denscheid Tel 49 2351 8701 0 Fax 49 2351 8701 100 Mail info strack de Web www strack de...

Reviews: