PAGE 30 — STOW G-4.5R A.C. GENERATOR— OPERATION & PARTS MANUAL — REV. #3 (03/13/06)
STOW G-4.5R — PREPARATION FOR LONG -TERM STORAGE
Generator Storage
For storage of the generating set for over 30 days, the
following is required:
■
Drain the fuel tank completely, or add STA-BIL to the fuel.
■
Run the engine until the gasoline in the carburetor is
completely consumed.
■
Completely drain the oil from the crankcase and refill with
fresh oil.
■
Remove the spark plug, pour 2 or 3 cc of SAE 30 oil into the
cylinder and crank slowly to distribute the oil.
■
Slowly rotate the engine a few times with the starter Rope and
install a new plug.
■
Pull out the starter rope slowly and stop at the compression
point.
■
Clean all external parts of the generating set with a cloth.
■
Cover the generating set and store in a clean, dry place.