Mask on enabled functions (Bit 0...7)
Mask on enabled functions (Bit8...15)
Here, you can specify the functions enabled via the
bus using a binary mask. The bits have the
following meaning:
Para
Bit
Valency
Function
0
1
controller on/off
1
2
control circuit 1 on/off
2
4
control circuit 2 on/off
3
8
Control circuit 1:
defrosting request
4
16
Control circuit 1:
super-frost request
5
32
Control circuit 1: reserved
6
64
Control circuit 1:
Set1 / Set2 change-over
7
128
Control circuit 1:
day / night change-over
8
1
Control circuit 2:
defrosting request
9
2
Function A: light 1
10 4
Function B: light 2
11 8
Function C: window heating
12 16
Function D: door frame
heating
13 32
Function E: blade scraper
14 64
Function F: reserved
15 128
reserved
To determine the value to be parameterised, all
valencies must be added up.
Password for parameter level
With this parameter, you can set the password for
parameter level
.
Relay contacts and
lamps
(password-protected)
...
Function relay K1...K8
Assignment of internal output signals to the
corresponding output relays.
...
Function LED 1...6
Assignment of status LEDs (signal lamps) to the
internal signals.
Function LED weekdays
If 1 is entered here, the 7 LEDs are assigned to the
weekdays. In this case, parameters
..
will
not be active. If 2 is entered, the LEDs will be
assigned according to parameters
...
.
...
Function LED 7…13 (Mo…Su)
Assignment of weekday LEDs to certain internal
signals (signal lamps).
Password of parameter level
With this parameter, you can set the password for
parameter level
.