8
NOTE
The following procedure presumes that the
operator manually initiates the unloading
sequence by pressing the U
NLOAD
push-
button. In some host-driven applications,
the application software may issue the
appropriate system software command to
initiate the same unloading sequence.
CAUTION
Never operate the cartridge insert/release
handle unless the green O
PERATE
H
ANDLE
indicator is lit steadily.
1. Press the U
NLOAD
push-button on the front panel’s
right side (or issue the appropriate system software
command). The yellow T
APE IN
U
SE
indicator blinks
as the tape rewinds.
2. When the green O
PERATE
H
ANDLE
indicator lights
steadily, pull the cartridge insert/release handle open
by pulling the bottom edge up and forward.
3. Remove the cartridge by pulling it forward from the
aperture.
4. Push the insert/release handle closed by pushing
front edge back and down.