background image

2

 

Legal Information

End-User License Agreement

The use of the products described in these materials is subject to the then current end-user license 

agreement, which can be found at the Stonesoft website:

www.stonesoft.com/en/support/eula.html

Third Party Licenses

The Stonesoft software includes several open source or third-party software packages. The appropriate 

software licensing information for those products at the Stonesoft website:

www.stonesoft.com/en/support/third_party_licenses.html

U.S. Government Acquisitions

If Licensee is acquiring the Software, including accompanying documentation on behalf of the U.S. 

Government, the following provisions apply. If the Software is supplied to the Department of Defense 

(“DoD”), the Software is subject to “Restricted Rights”, as that term is defined in the DOD Supplement to 

the Federal Acquisition Regulations (“DFAR”) in paragraph 252.227-7013(c) (1). If the Software is supplied 

to any unit or agency of the United States Government other than DOD, the Government’s rights in the 

Software will be as defined in paragraph 52.227-19(c) (2) of the Federal Acquisition Regulations (“FAR”). 

Use, duplication, reproduction or disclosure by the Government is subject to such restrictions or successor 

provisions.

Product Export Restrictions

The products described in this document are subject to export control under the laws of Finland and the 

European Council Regulation (EC) N:o 1334/2000 of 22 June 2000 setting up a Community regime for the 

control of exports of dual-use items and technology (as amended). Thus, the export of this Stonesoft 

software in any manner is restricted and requires a license by the relevant authorities.

General Terms and Conditions of Support and Maintenance Services

The support and maintenance services for the products described in these materials are provided pursuant 

to the general terms for support and maintenance services and the related service description, which can be 

found at the Stonesoft website:

www.stonesoft.com/en/support/view_support_offering/terms/

Replacement Service

The instructions for replacement service can be found at the Stonesoft website:

www.stonesoft.com/en/support/view_support_offering/return_material_authorization/

Hardware Warranty

The appliances described in these materials have a limited hardware warranty. The terms of the hardware 

warranty can be found at the Stonesoft website:

www.stonesoft.com/en/support/view_support_offering/warranty_service/

Trademarks and Patents

The products described in these materials are protected by one or more of the following European and US 

patents: European Patent Nos. 1065844, 1189410, 1231538, 1231754, 1259028, 1271283, 1289183, 

1289202, 1304830, 1304849, 1313290, 1326393, 1361724, 1379037, and 1379046 and US Patent 

Nos. 6,650,621; 6,856,621; 6,912,200; 6,996,573; 7,099,284; 7,127,739; 7,130,266; 7,130,305; 

7,146,421; 7,162,737; 7,234,166; 7,260,843; 7,280,540; 7,325,248; 7,360,242; 7,386,525; 

7,406,534; 7,461,401; 7,573,823; 7,721,084; and 7,739,727 and may be protected by other EU, US, or 

other patents, or pending applications. Stonesoft, the Stonesoft logo and StoneGate, are all trademarks or 

registered trademarks of Stonesoft Corporation. All other trademarks or registered trademarks are property 

of their respective owners.

Disclaimer

Although every precaution has been taken to prepare these materials, THESE MATERIALS ARE PROVIDED 

"AS-IS" and Stonesoft makes no warranty to the correctness of information and assumes no responsibility 

for errors, omissions, or resulting damages from the use of the information contained herein. All IP 

addresses in these materials were chosen at random and are used for illustrative purposes only.

Copyright © 2012 Stonesoft Corporation. All rights reserved. All specifications are subject to change.

Revision: AIG_Stonesoft_FW-1030_1060_20121026

Summary of Contents for FW-1030

Page 1: ...Appliance Installation Guide Stonesoft FW 1030 and FW 1060...

Page 2: ...ese materials are provided pursuant to the general terms for support and maintenance services and the related service description which can be found at the Stonesoft website www stonesoft com en suppo...

Page 3: ...which can be found at the Stonesoft website Contents Installation Procedure 4 Product Documentation 4 Safety Precautions 5 Unpacking the Appliance 7 Front Panel 8 Back Panel 9 Rack Mounting 10 Connec...

Page 4: ...Initial Configuration page 16 Product Documentation Press F1 in any Management Client window to view the Online Help All PDF guides are available On the Management Center CD ROM in the Documentation...

Page 5: ...y one hand when working with powered on electrical equipment This is to avoid making a complete circuit which will cause electrical shock Use extreme caution when using metal tools which can easily da...

Page 6: ...ot open the power supply casing Power supplies can only be accessed and serviced by a qualified technician of the manufacturer Operating and Storage Temperatures The allowed operating temperature of t...

Page 7: ...he appliance was shipped in and note if it was damaged in any way If the appliance itself shows damage file a damage claim with the carrier who delivered it Confirm that the Stonesoft anti tamper tape...

Page 8: ...system even when the appliance is turned off Table 1 Power and Disk Activity Indicators Indicator Status Explanation Power Blue Indicates power is being supplied to the system s power supply unit This...

Page 9: ...ty Unlit No link Amber Link ok Link Unlit Speed is 10 Mbps Green Speed is 100 Mbps Orange Speed is 1 Gbps Table 3 SFP Port Indicators on FW 1060 SFP Indicator Status Explanation Activity Unlit No link...

Page 10: ...cal noise and electromagnetic fields are generated Leave enough clearance in front of the rack to enable you to open the front door completely 63 cm 25 inches Leave enough clearance in the back of the...

Page 11: ...to prevent components falling off from the appliance Be sure to install an AC power disconnect for the entire rack assembly This power disconnect must be clearly marked The rack assembly must be prope...

Page 12: ...the front panel illustration for the location of the holes 2 Repeat step 1 with the bracket on the other side of the appliance Proceed to Connecting the Cables page 14 Installing the Appliance Into a...

Page 13: ...h the bracket on the other side of the appliance 4 Attach each bracket to the rack using two screws and cage nuts Insert the screws through the holes in the front of the bracket one screw through the...

Page 14: ...0 SFP has two SFP ports ports 6 7 You can use these ports as either copper or fiber ports by inserting a small form factor pluggable SFP transceiver for copper or fiber optic cable in the port slot No...

Page 15: ...ngs Network cards at both ends of each cable must have identical speed duplex settings This also applies to the automatic negotiation setting if one end of the cable is set to autonegotiate the other...

Page 16: ...erver as outlined in the sections below To successfully complete this configuration the following prerequisites must be met The Firewall element must be defined in the Management Center You must have...

Page 17: ...If you configure the engine with a USB stick you must set a password for the root account in the Management Client to enable command line access to the engine If you want to allow remote access to the...

Page 18: ...he appliance using the power on off switch The engine bootup process is shown in the console and after some time the engine configuration wizard starts To select the configuration method 1 Do one of t...

Page 19: ...sing the arrow keys and press ENTER 2 Select the correct timezone in the dialog that opens Note If the desired keyboard layout is not available use the best matching available layout or select US_Engl...

Page 20: ...n your keyboard to select the option and allow remote access to engine command line using SSH 4 Highlight Next and press ENTER The Configure Network Interfaces window is displayed Note It is not neces...

Page 21: ...gement Server 4 Highlight Next and press ENTER to continue Contacting the Management Server The Prepare for Management Contact window opens If the initial configuration was imported most of this infor...

Page 22: ...licy that allows only administration related connections and blocks everything else In the second part of the configuration you define the information needed for establishing a trust relationship betw...

Page 23: ...anagement Server Contact After you see a notification that Management Server contact has succeeded or the appliance has rebooted itself after automatic configuration with a USB stick the firewall engi...

Page 24: ...sion it automatically switches to the previous configuration at the next reboot You can also switch back to the previously installed software version manually as instructed here whenever necessary To...

Page 25: ...Press Enter A list of available commands opens 5 Select System Restore Options and press Enter 6 Type 1 and press Enter to clear the settings A confirmation prompt is shown 7 Type YES and press Enter...

Page 26: ...Unplug all power cords from the system or the wall outlets 4 Disconnect the cable from the SFP transceiver 5 Pull down the latch on the transceiver 6 Pull the SFP transceiver carefully out of the port...

Page 27: ...documentation See inside for further details All documentation and our technical knowledge base is available at www stonesoft com support Copyright 2012 Stonesoft Corporation Stonesoft Inc Americas He...

Reviews: