StoneFly USO-HA Setup Guide
Software Configuration
© 2020 StoneFly, Inc. | All Rights Reserved.
P a g e
| 52
Navigate to
Network > Data Port
. The Local iSCSI Data Port Settings screen will
appear with the current system (factory) settings. Most fields are blank.
StoneFusion Local iSCSI Data Port Settings Screen
Enter the
IP Address
for the Local iSCSI Data Port. Enter the
NetMask
setting for the Local
iSCSI Data Port. Click
Submit
.
Click
OK
to continue when the confirmation dialog box appears. The USO
automatically configures the Network and Broadcast settings based on the IP address and
Netmask settings.
Click on the
Advanced: Network/Broadcast
link to view or modify the Network and
Broadcast settings. For more information, see “Chapter 2: Administrative Interface” in the
Storage Concenter User’s Guide.
Review the status of all SAN Network Interfaces to select which ports will be used. It is
not necessary to select all available ports. All ports selected must have cables attached to
them to maintain the proper cluster configuration and operation. The
Id
button is used to
flash the link light on a specific port. Select a port by clicking on the box in the
Bond
column.
Changes are not enforced until the next reboot.