Stone Art 963149 Instructions Download Page 4

CARE AND MAINTENANCE 

 

1.  Keep the water clean and clean the fountain periodically to prevent mineral deposits and contamination which may 

clog the pump. 

2.  Use a pre-filter on your pump if available. 
3.  Regular cleaning of the pump will be necessary depending upon the environment in which it is operated.  Clean the 

pump when it is visibly soiled or when a noticeable drop in performance is detected.  

 

Failure to clean the pump will result in overheating of the pump and the voiding of the warranty!

 

4.  Before cleaning, always disconnect the pump from the power source. 
5.  Disassemble the pump by removing the inlet screen & the impeller housing. Remove the impeller/rotor assembly by 

gently pulling on the impeller blades. Use a soft cloth or brush to clean the area inside of the pump where the 
impeller/rotor assembly was. Clean the inlet screen, impeller housing & impeller in warm soapy water. Reassemble 
the pump and inspect for proper operation. 

6.  Check the water level regularly, to ensure the pump is completely submerged during operation. 
7.  To eliminate water damage to floors and/or surrounding fountain areas, check for leaks and excessive splashing after 

initial installation and on a regular basis. 

8.  Place the fountain in a location that will not be damaged should the area come in contact with liquids. 
9.  If the fountain is not in use for an extended period of time, disconnect the power and empty all the water from the 

fountain. 

10.  The fountain should not be operated in temperatures below 41° Fahrenheit (5° Celsius) to prevent frost damage.  If 

the fountain is stored outdoors in freezing temperature, disconnect the power, empty all the water from the fountain 
and make sure it is completely dry. 

 

 
Light Bulb Replacement Instructions: 

1.  If an accent light bulb is burned out, unplug the transformer from the power source and allow a few minutes for the 

light bulb to fully cool before handling. 

2.  Detach the lamp from the lamp clip and remove the bulb shell by firmly grasping and twisting the tube away from the 

bulb socket. (See Diagram 1) 

3.  The bulb may now be pulled out from its socket and replaced with a new bulb (See Diagram. 2). 

 

Replacement for the high intensity halogen bulb: JC type, 12v submersible bulb, 10 watts maximum. 

 

 
 

 

IMPORTANT SAFETY INSTRUCTIONS PERTAINING TO A RISK OF FIRE, OR INJURY TO PERSONS         

ns or  

w the lamp to cool before handling the lamp. 

th. Oil from skin may damage lamp. 

 

is no water flow… 

rrect. 

 the pump operates, but there is no water flow and the pump is fully submerged and the supply tubing has no kinks… 

let. 

             WARNING - Lighted lamp is HOT quickly.  Contact only the switch when turning on. Do not touch hot le
 cover. 
 

Unplug and allo

 

Keep lamp away from materials that may burn. 

 

Do not touch the bulb at any time. Use a soft clo

 

Do not operate the lamp with a missing or damaged lamp covers. 

 
 

Troubleshooting Guide:

If the pump operates, but, there 
 

1. Check to make sure the pump is fully submerged. 

 

2. Check the supply tube for any kinks or folds and co

 
If
 

1. Disconnect the pump from the power source. 

 

2. Disconnect the supply tube from the pump out

 

3. Check for clogs or holes and clean the tubing inside and outside if necessary. 

 

4. Check for clogs and clean the pump inlets and outlet if necessary. 

 

5. Place the pump back into the water outlet side up and then re-connect the pump to the power source. 

 

6. Once the water begins to flow from the pump, re-connect the supply tubing to the pump outlet.  

 

 

 

Note:  

Each fountain product may have minor variations in texture, finish and appearance.  Some products and finishes are 

intentionally weathered and worn in appearance to enhance the aesthetic beauty of the finished product and make each 
fountain truly unique. 

 

Reviews: