Stone Age Mezzo SA-MPO-VFC Installation And Operation Instructions Manual Download Page 5

 

5

B.  If installing the unit at the pad level, align and set 
the Base Plate directly on the footing, ensuring it is 
plumb and level.  See Figure 7. 

 

 

 

 

C.  Install the lower sidewalls (2), ensuring they are 
level and square.  Plan for the location of the gas line 
for the vent free log set, as you will typically want to 
locate it in the lower sidewall, approximately 4” from 
the bottom, on the right side wall.  Drill a hole large 
enough  to  accommodate  the  gas  line,  using  a  drill 
masonry bit. See Figure 8. 

 

 

 

D. Install the middle sidewalls (2), ensuring they are 
level and square.  See Figure 9. 

 

 

 

 

E. Install the back plate (3).  See Figure 10. 

 

 

 

F.  Install  upper  sidewalls  (4L)  and  (4R),  ensuring 
the  correct  piece  is  placed  in  position.    The  correct 
position is when the inner wall, outer wall and front 
are parallel with the middle wall pieces.  Place each 
so  the  front  is  set  back  3½  inches from  the  front of 
the middle wall piece below.  See Figures 11 & 12. 

 

 

 
 

 

 

 

 

 

Figure 7. Base Plate on Pad 

Figure 8. Lower Sidewalls 

Figure 9. Middle Sidewalls 

Figure 10. Back Plate 

Figure 11. Upper Sidewalls 

5R

4L

4R

4L

4R 

Figure 12. Upper Sidewalls –Top View

Base Plate 

Concrete Pad 

Summary of Contents for Mezzo SA-MPO-VFC

Page 1: ...ure 2 Components are listed in Table 1 Some pieces are larger and shaped differently than required for installation and are in tended to be field cut to fit These are showing in Fig ure 2 with red arr...

Page 2: ...taller to determine the proper chimney system for this field conversion Note 1 This Fireplace is intended for use with vent free gas logs only The oven appliance is intended for use with wood only Not...

Page 3: ...is acceptable to install this kit on a preex isting reinforced concrete patio if the soil is stable and such installation is not prohibited under local building code If the kit is not being installed...

Page 4: ...concrete blocks Two courses of 8 tall block will be slightly shorter than the riser legs of the kit 3 2 Assembly of Components Components that become broken during shipment and handling can be mortare...

Page 5: ...masonry bit See Figure 8 D Install the middle sidewalls 2 ensuring they are level and square See Figure 9 E Install the back plate 3 See Figure 10 F Install upper sidewalls 4L and 4R ensuring the corr...

Page 6: ...he brick laid on edge See Figure 15 J Install firebrick on the side walls with the brick laid on edge The brick lay up on approximately 1 3 of the upper sidewall and a notch should be cut in the front...

Page 7: ...s of the oven base plate and a create a z pattern of mortar through the middle area under the oven base plate aligning it with the front edge of the base plate extension and centering it from side to...

Page 8: ...nt wall Use shims to tempo rarily hold the wall piece in place while working mortar into the joint using a joint tool Completely bed and fill the joint with mortar See Figure 24 S Install the enclosur...

Page 9: ...e Figure 27 V Cut out the front corners of the roof panels 15 to clear the oven chimney as outlined in red approx imately 14 from the front and 5 from the side Using the pieces cut from the roof panel...

Page 10: ...terials in the vicinity of the oven and fireplace openings may be at risk WARNING WHEN OPERATING THE MEZZO VENT FREE COMBO WEAR PROPER CLOTHING AND USE PROPER OVEN AND FIREPLACE TOOLS WITH EACH APPLIA...

Page 11: ...d will smoke The pressure of moisture and resin inside green wood will build under heat and explode as sparks Therefore it is recommended that only sea soned wood be used in your fireplace Most wood r...

Page 12: ...s a result creosote residue accumulates on the flue lining When ignited this creosote makes an ex tremely hot fire The chimney shall be inspected at least twice a year during the heating season to det...

Page 13: ...ther conditions type of finish material size of mortar joints and skill and efficiency of the mason or install er Table 4 does not account for waste Add the appropri ate waste factor for your material...

Page 14: ...14 2 Base Plate 4 Back Plate 8 Throat 1 Riser Leg 1A Cross Leg 6 Rear Header 3 Lower Middle Side Wall 7S Straight Lintel 5L R Upper Side Wall...

Page 15: ...ng defects in the Stone Age product and does not cover de fects or faulty workmanship in the installation of the product or the ma sonry or other structure in which it is installed Also this warranty...