-9-
-8-
2
2
1
3
1
6
6
5
4
STOLZENBERG
Kehrmaschinen
20122006
·MATRIXMTX-900-V/-B/-VBTRS·
·MATRIXMTX-900-V/-B/-VBTRS·20122006
STOLZENBERG
Kehrmaschinen
Filter cleaning
To consistently attain the best possible cleaning results, you must always clean the
lamellar filter prior to emptying the dust bin.
Likewise, you should also clean the filter if particularly dusty areas are swept, or if
dust is whirled up during sweeping.
The sweeper has been equipped with a mechanically operated vibrating device to
clean the lamellar filter.
To remove stubborn dirt, you should use a brush to clean off the filter or take out the
filter and gently knock off the dirt.
•
•
•
•
•
Turn off the sweeper (all actuators).
Make sure the sweeper has been secured from rolling away by accident.
Open the hood.
On the top of the ejector's trim panel
two slides
are located.
Swiftly slide these slides back and forth.
-3-
-1-
These slides initiate a vibrating mechanism, which works loose the dust from the lamellar
filter. The worked off dust drops directly into the dustbin.
Removing the filter
The sweeper has to be off if you're planning to take out the filter.
(all actuators off)
-2-
-3-
•
•
•
•
•
•
Turn off the sweeper (all actuators).
Make sure the sweeper has been secured from rolling away by accident.
Remove the dustbin.
Open the hood.
Remove these wing nuts.
Pull out the filter frame
with the filter
from the trim panel of the ejector
in the
direction of the dustbin retainer
Two wing nuts
are located on the trim panel of the ejector
.
-4-
-5-
-2-
In addition, the following applies to MTX-900-V TRS and MTX-900-VB TRS
Disposal
Disposal of defective parts, specifically electric component parts, batteries and plastic
elements in compliance with legislator's waste disposal regulations.
Installing the filter
The sweeper has to be off if you're planning to install the filter.
(all actuators off)
-5-
-4-
-4-
-5-
-3-
-6-
-2-
•
•
•
•
Set the filter
in the filter frame
.
Make sure the filter fits correctly.
Insert the filter frame
with the filter
from the side of the dustbin retainer into the trim
panel of the ejector
in such a way as to ensure the cup square neck bolt
of the filter
frame will fit through the bore holes of the trim panel of the ejector.
Make sure the bolts fit correctly. The square of the bolt has to fit into the square recess of
the filter frame.
Firmly push the filter with its filter frame against the trim panel of the ejector.
Screw tight the two wing nuts
on the threads of the cup square neck bolts of the filter
frame.
Maintenance Chart
Daily maintenance
After each 50 operating hours also
-
-
Charge battery.
Check if machine is damaged or impaired in any way.
Empty dust container.
Search brush - roller tunnel for jammed particles and seized up dirt that may narrow the brush tunnel and
obstruct free roller brush movement.
Check condition of dust filter and clean if necessary.
Check if sweeping rollers are worn or cluttered. Replace if required.
Check sweeping contour, readjust if required.
Check if side brush adjustment is worn, if required readjust or replace.
Check cable isolation, replace cables if required.
Search suction for obstacles, clean.
Check if roller drive chain is elongated or loosened.
Check all bearings for wear.
Check if seals are damaged or dislocated.
Check if cable connections are tight.
Clean dust filter, replace if necessary.
-
-
-
-
-
-
-
-
-
-
-
-
-
After each 100 operating hours also
In addition, the following applies to MTX-900-V TRS and MTX-900-VB TRS
In addition, the following applies to MTX-900-V TRS and MTX-900-VB TRS
No operation of one of
the electrical consumers:
Sweeping result
unsatisfactory:
Check plug connections
Charge battery
Lower
Adjust
Check if roller trim panel is impaired by jammed
debris. Correctly fitted?
if required switch off side brushes
Dismount brush rollers and clean them
Check side brushes and remove obstacles
Jack up the Sweeping & Suction Machine
check wheels and free running
Open the ventilation flap
Clean filter
check for tight fit
check if false air is sucked in
Check ventilator wheel and remove any obstruction
F
B
S
Drive wheels obstructed
F
F
mer
ault in electrical wiring
attery empty
Side brush(es) or main sweeping rollers
not lowered
ide brush(es) or main sweeping
rollers worn
Trajectory clogged by dirt
Sweeping roller(s) do not operat
Brush rollers are jammed by dirt,
cords, strings or the like
ilter heavily polluted
ilter not correctly fitted
Leakage and subsequent aspiration of
false air in the filter chamber
Ator does not move freely
Disturbances - Disturbance Display and Remedy
Disturbance
Possible Cause
Remedy
In addition, the following applies to MTX-900-V TRS and MTX-900-VB TRS
Summary of Contents for MATRIX MTX-900 TRS
Page 11: ......