Command
Function
Feedback Example
%9974.
Check the HDCP status of the outputs.
Out 1 2 3 4
HDCP N N N N
%9975.
Check the I/O connection status.
Out 01 02 03 04
In 04 04 04 04
%9976.
Check the output resolution.
Out 1 1920x1080
Out 2 1920x1080
Out 3 1920x1080
Out 4 1920x1080
%9977.
Check the status of digital audio of output
channels.
Out 1 2 3 4
Audio Y Y Y Y
%9978.
Check the HDCP compliant status of the
inputs.
In 01 02 03 04
HDCPEN Y Y Y Y
4.4 TCP/IP Control
SUHM44HB boasts option TCP/IP port for IP control.
Default settings: IP: 192.168.0.178; Subnet Mast: 255.255.255.0; Gateway: 192.168.0.1;
Serial Port: 8080.
IP& gateway can be changed as you need, Serial Port cannot be changed.
Connect the Ethernet port of control device and TCP/IP port of SUHM44HB, and set
same network segment for the 2 devices, users are able to control the device via
web-based GUI or designed TCP/IP communication software.
4.4.1 Control Modes
SUHM44HB can be controlled by PC without Ethernet access or PC(s) within a LAN.
Controlled by PC
Connect a computer to the TCP/IP port of the SUHM44HB, and set its network segment
to the same as the SUHM44HB
’s.