Installation
Incorrect installation or unheeded warnings could result in
a serious fire, and loss of life and property.
Product is
NOT
designed for installation in “zero-clearance” fireboxes
or mobile homes, or in conjunction with gas log sets.
Inspect the chimney flue and fireplace for loose mortar, damaged
brick, and creosote build-up. Contact a professional chimney sweep or
building contractor for more information or repair.
Slide unit into fireplace opening, making sure to center unit in the
opening. Use feet adjustment bolts to level unit. Make sure insulation
is properly installed; covering all gaps without being bunched up. Note
that large gaps created by rough openings may require additional in-
sulation.
Route the blower cord to desired location. Plug in the cord and check
for proper blower operation. See “Blower” section in Operating In-
structions for explanation of switches.
Operating Instructions
Fuel:
WARNING:
Never use gasoline, oil, or any other flammable liquid to
start a fire!
Dry, seasoned hardwood is the safest and most efficient firewood. Rec-
ommended firewood age is 6-9 months.
When wood is green and/or burned very slowly, it produces tar and
other organic vapors, which combine with expelled moisture to form
creosote. This creosote residue accumulates on the flue lining, and
when ignited, can start an extremely hot chimney fire. The chimney
should be inspected for creosote build-up twice monthly during the
heating season, and cleaned as necessary.
Make certain to keep wood well back from the door opening in order to
avoid puncturing or placing extreme heat on the glass.
Regulate the fire in order to avoid the dangers and unnecessary wear
associated with extreme heat and uncontrolled burning.
Ashes should be placed in a metal container with a tight fitting lid and
retained there until all cinders have thoroughly cooled. Remember
that bottom, sides, and handles of container may be very hot.
Blower:
Blower is operated by variable speed switch. To turn on, turn switch
clockwise until desired fan speed is achieved. To turn off, turn switch
counter-clockwise until a positive “click” is heard. Unit is also
equipped with a thermostatically controlled switch which turns
blower off when temperature drops below 90
°
F.
In event of power failure, only burn unit with doors open.
WARNING:
Disconnect power source prior to performing any mainte-
nance or diagnostic operation on the blower or switches!
Assembly
Incorrect assembly or unheeded warnings could result in a
damaged unit, or a serious fire and loss of life and property.
Refer to included photo addendum to aid in assembly.
Step 1.
Unpack Heat Grate and identify all parts using Parts List.
Step 2.
Place Heat Grate unit on a flat surface to prepare for assem-
bly. Be sure to orient the unit with the manifold facing you.
(Fig. 1)
Step 3.
Choose if you want to place the Blower Assembly on the left or
right side of the fireplace. This is determined by where you want the
Power Cord to exit the unit. Remove cover from Blower Assembly.
Place Blower Assembly on desired side of Heat Grate by tipping the
Heat Grate up and sliding the manifold down between the Blower As-
sembly box and heat shield.
Step 4.
Align holes and bolt the Blower Assembly to the Heat Grate
unit using supplied Philips head screws.
(Fig. 2)
Step 5.
Route Cord out of the Blower Assembly on the proper side. Be
sure to place rubber grommet in case opening.
(Fig. 3)
Step 6.
Connect Cord wires to Blower and Switch wires by joining ter-
minals. Connect Green Wires to each other. Connect White from
Power Cord to Black from Fan. Connect Black from Power Cord to
Black from Switch.
See wiring diagram for more info.
(Fig. 4)
Step 7.
Place Blower Vent Assembly on opposite side of Heat Grate
from the Blower Assembly. Bolt to Heat Grate in same manner as
Blower Assembly in Step 4.
(Fig. 5)
Step 8.
Assemble Cover by sliding the two cover pieces together. Place
Variable Speed Switch through hole in cover. Trim ends of Cover to fit
into the fireplace opening. Place caps on each end of the Cover, mak-
ing sure to use Cap with cord cutout on the side where the Cord exits
the unit.
(Fig. 6)
Step 9.
Slide assembled unit into fireplace. Use feet adjustment bolts
on bottom of feet to level unit in fireplace.
(Fig. 7)
Step 10.
Install doors on top of cover and plug Grate Heater power
cord into 110v electrical outlet.
1 - Heat Grate Unit
1 - Blower Assembly
1 - Blower Vent Assembly
1 - 6’ Cord
1 - Variable Speed Switch
1 - Adjustable Cover w/ end caps
1 - Hardware Pack
(1 Grommet & 4 Philips Head Screws)
Parts List
Grate Heater
For wood-burning masonry fireplaces