background image

11

4.1  OVERRUN ADJUSTMENT

The product when served is a combination of air and mix.
Overrun is a measure of the amount of air blended into the
mix.

Overrun can be expressed in terms of the amount of weight
loss for a given volume.  For example, if a pint of liquid mix
weighs 18 ounces and a pint of frozen product with air
added weighs 12 ounces, the over-run is said to be 50
percent (18 oz. - 12 oz. = 6 oz., (6 /12) x 100 = 50%.

The overrun can be checked by placing a one pint container
on an ice cream scale and zeroing out the scale.  Then fill
a one pint container with frozen product.  The container
should be filled over the top and leveled with a straightedge.
The product should not contain any air pockets.  When
weighed on an ice cream scale, one pint of product should
weigh 12 to 13 ounces.

The mix pump has been preset at the factory to produce
a product with approximately 40% overrun.  Because of
differences in mix formulation, temperatures and baro-
metric pressure, this figure may vary.  It will be necessary
for approximately 2 gallons of mix to be pumped thru the
freezer before changes in the product are noticeable due
to adjustments in overrun.

Overrun is controlled by the length of the air compressor
piston stroke within the piston cylinder.  Lengthening the
stroke within the cylinder will increase overrun.  Con-
versely, shortening the stroke will decrease overrun.  To
perform an overrun adjustment, refer to the following
procedure:

A. Turn the mix pump switch to the OFF position and

unplug the mix pump from its grounded 115V
receptacle.

B. Remove the 2 electrical box cover screws and

remove the electrical box cover.

C. On air compressor side of pump, locate the long/

slender piston rocking arm. The rocking arm down-
ward travel is limited by a stationery cam. On the face
of the cam there is an overrun setting indicator plate
numbered 3 thru 8 and an adjustment knob (Fig. 7).

D. The overrun setting is indicated by a pointed pin.

E. To adjust overrun, loosen the allenhead screw

(located within the center of the adjustment knob)
with the 5/32" allen wrench provided. Rotate the
adjustment knob counterclockwise to a higher
number for higher overrun, or clockwise to a lower
number for lower overrun. Each number multiplied
by 10 represents the overrun percentage (ie: #4 =
40% overrun).

SECTION 4

MAINTENANCE  INSTRUCTIONS

Figure 7

Overrun Adjustment

F. Tighten the allen screw, then place the wrench back

in its clip.  Replace the electrical box cover and
screws, plug the mix pump into its grounded 115V
receptacle and turn the mix pump power switch to
the ON position.

4.2  PREVENTATIVE MAINTENANCE

To assure trouble free operation and consistent overrun
when using the U3 mix pump, we must follow mix hose
repositioning and replacement procedures. The follow-
ing is the preventative maintenance schedule:

A. MIX PUMP HOSE REPOSITION (every one or two

weeks.)

NOTE

Mix pump hose must be repositioned every 1 - 2
weeks. Failure to comply will result in reduced mix
pump liquid capacity, dispense stoppage, popping,
and possible mix pump hose leakage.

1. Run cleaning solution through pump.

2. Turn pump off and if connected to freezer, relieve

any pressure by opening the spigot.

3. Grasp the pick-up hose end of the mix pump hose

with one hand and turn the pump on. Pull down on the
pick-up hose end until 12 to 14 inches of tubing has
reversed fed through the pump, then turn the pump
off.

4. Loosen small clamp at the pick-up hose adapter and

disconnect mix pump hose.

5. Cut 7-1/2 inches off the end of the mix pump hose.

The height of the pump can be used to measure. See
Figure 8.

OVERRUN
ADJUSTMENT

Summary of Contents for U3-02A

Page 1: ...U3 02A Mix Pump Manual No 513606 Rev 0 April 2004 Owner s Service Manual ...

Page 2: ......

Page 3: ... equip same on mix pump built prior to date of change DONOTATTEMPTtooperatethemixpumpuntilinstructionsandsafetyprecautionsinthemanualarereadcompletely and thoroughly understood The mix pump should be operated only by qualified personnel If problems develop or questionsariseinconnectionwiththeinstallation operation orservicingofthemixpump contactyourlocaldistributor or the company at the following ...

Page 4: ...ghlight specific safety information the following safety definitions are provided to assist the reader The purpose of safety symbols is to attract your attention to possible dangers The safety symbols and their explanations deserve your careful attention and understanding The safety warnings do not by themselves eliminate any danger The instructions or warnings they give are not substitutes for pr...

Page 5: ...NSTRUCTIONS 7 3 1 Safety Precautions 7 3 2 Pump Motor Switch 7 3 3 Operation Of U3 Mix Pump 7 3 4 Cleaning 8 3 5 Disassembly and Inspection of Removable Parts 8 3 6 Sanitizing and Startup 9 3 7 Cleaning Mix Lines 10 SECTION 4 MAINTENANCE INSTRUCTIONS 11 4 1 Overrun Adjustment 11 4 2 Preventative Maintenance 11 SECTION 5 TROUBLESHOOTING 13 SECTION 6 REPLACEMENT PARTS INFORMATION 15 6 1 How to Order...

Page 6: ...Pickup Hose 4 C Pickup Hose 4 3 Mix Pump Installation 5 D 3 wayTee Connection 5 4 Pump Motor Switch 7 5 Mix Pump Operation 8 6 Removing Parts 8 7 Overrun Adjustment 11 8 Reposition Mix Pump Hose 12 9 Pump Roller Assembly 12 10 Pump and Decal Assembly 15 Exploded Parts Illustrations 17 21 Wiring Diagram 22 ...

Page 7: ... to the freezing cylinder of your freezer quickly and conveniently Second the U3 02A Pump precisely injects a preset amount of air into the mix maintainingoverruntoassuremaximumprofitability Third itpressurizesthefreezingcylinder forcingfrozenproduct through the spigot at the rapid dispense rates needed by high volume locations SECTION 1 INTRODUCTION 1 2SPECIFICATIONS WEIGHT 24 lbs 10 89 kg DIMENS...

Page 8: ...2 ...

Page 9: ...2 B The product at the mix pump and in transfer lines must be maintained below 41 F 5 C 2 3 INSTALLATION A Follow the steps below to install the mix pump in an upright position on the wall using optional pump mounting kit Allow clearance for a mix container under pump See Figure 2 1 Mount by locating four 4 hole centers on cooler wall using mounting bracket as template WARNING Risk of Personal Inj...

Page 10: ...hose to feed itself thru the pump until 6 remains on the entering side 5 Turn pump off 6 Connect mix pump hose to pickup hose adapter using small hose clamp See Figure B CAUTION Risk of Product Damage Avoid twistingmixpumphosewhilefeedingintocover Twisting the hose may cause the hose to rupture Figure B Figure C 7 Turn pump on 8 Gently pull on the discharge hose to help remaining 6 of mix pump hos...

Page 11: ...5 ...

Page 12: ...6 ...

Page 13: ...h Fig 4 is located on the mix pump assembly When the pump motor switch is placed in the ON position the mix pump motor will be actuated to pump mix into the freezer cylinder When the set pressure is reached the mix pump will shut off automati cally When the pump motor switch is placed in the OFF position the mix pump will be inoperative SECTION 3 OPERATION INSTRUCTIONS Figure 4 Pump Motor Switch N...

Page 14: ...8 ...

Page 15: ...er with mix Sanitizing the night beforeisnoteffective Tosanitize refertolocalsanitaryregulationsforapplicable codesandrecommendeddisinfectingproductsandproce dures The frequency of cleaning must comply with local health regulations Use a solution containing 100 PPM of free available chlorine Use Stera Sheen Green Label Sanitizer and Cleaner or others in accordance with HealthInspectionRequirements...

Page 16: ...g the pump and freezer as an assembly Once every 2 weeks if required perform the following steps A Mix 2 gallons 7 5 liters of milkstone remove solution according to the directions on the container and pump through the mix line B Cut a piece of sponge slightly larger than the inside diameter of the mix line Place the sponge inside the mix line and force through with tap water pressure A garden hos...

Page 17: ...rm down ward travel is limited by a stationery cam On the face of the cam there is an overrun setting indicator plate numbered 3 thru 8 and an adjustment knob Fig 7 D The overrun setting is indicated by a pointed pin E To adjust overrun loosen the allenhead screw located within the center of the adjustment knob with the 5 32 allen wrench provided Rotate the adjustment knob counterclockwise to a hi...

Page 18: ...12 Roller Cover Clamp Inlet Side Discharge Side Cover Clamp Discharge Inlet Roller ...

Page 19: ...SSURE IN THIS CASE TURN THE PUMP OFF DRAW 2 3 PINTS TO REDUCE SYSTEM PRESSURE TO ZERO TURN PUMP ON PURGE REMAINING AIR IN MIX BAG AND PICK UP HOSE IMPORTANT Before connecting the pick up hose to the mix bag purge the mix bag of air to the extent possible Out of Mix Replenish mix supply MIx pump hose kinked inside black cover clamp Follow mix pump hose jammed repair See 1 above Hoses assembled inco...

Page 20: ... R t u o h c l e b o t r i a s s e c x e w o l l a d n a y l l u f t o g i p s n e p O E V O B A 4 2 E E S O S L A E T O N P M U P M O R F E G A K A E L X I M 8 n a e l c d n a e l b m e s s a s i d y l e t a i d e m m i s t i s o p e d x i m d e i r d m o r f e g a m a d p m u p x i m t n e v e r p o T N O I T U A C p m u p d e d e e c x e s i e f i l e c i v r e s e s o h p m u p x i M r e w o p...

Page 21: ...ibutor or the company with the followinginformation A Model number of equipment B Serial number of Model Stamped on nameplate C Part number part name and quantity needed Many part names and numbers are listed in this manual NOTE Minimum Billing is 50 00 Net 6 2 PARTS LIST AND REFERENCE DRAWINGS The following lists and drawings will aid the user when ordering parts or servicing the mix pump ...

Page 22: ...16 ...

Page 23: ...17 ...

Page 24: ...18 ...

Page 25: ...19 ...

Page 26: ...20 ...

Page 27: ...21 ...

Page 28: ...22 ...

Page 29: ...oelting prompt written notice of any claimed breach of warranty within the applicable warranty period and c delivers the affected equipment to Stoelting or its designated service location in its original packaging crating also within that period Buyer shall bear the cost and risk of shipping to and from Stoelting s plant or designated service location 4 Extensions The warranty period for deinstall...

Page 30: ...24 ...

Reviews: