D. The floor model freezers are equipped with air-cooled
condensers and require correct ventilation. The front of
the freezer is the air intake and must be unobstructed.
Air discharges out of the rear of the unit. Do not obstruct
the discharge. Allow a 6" (15.2 cm) clearance behind
the unit (Fig. 8).
CAUTION
FAILURE TO PROVIDE ADEQUATE VENTILATION WILL
VOID WARRANTY!
Figure 8
Space and Ventilation Requirements
E. Place the ON-OFF-STIR ONLY toggle switch in the
OFF position. This switch is located on the lower left of
the freezer, under the drip tray and cover.
F. Connect the power cord. The plug is designed for 115
volt/15 amp duty. The unit must be connected to a
properly grounded receptacle. The electrical cord
furnished as part of the freezer has a three prong
grounding type plug (Fig.9). The use of an extension
cord is not recommended. If one must be used, use one
with a wire, size 12 gauge or heavier, with a ground. Do
not use an adaptor to avoid grounding equipment.
Figure 9
Electrical Plug
CAUTION
DO NOT ALTER OR DEFORM PLUG IN ANY WAY!
Figure 10
Installing Drip Tray and Cover
G. Install the drip tray support, drip tray, drip tray grid,
cover and miscellaneous parts on the freezer. (Fig. 10)
Summary of Contents for E157
Page 1: ...Model E157 E257 F257 SERVICE MANUAL Manual No 513565 Rev 2 June 2003...
Page 2: ......
Page 4: ......
Page 16: ...8...
Page 28: ...20...
Page 30: ...22...
Page 40: ...32...
Page 46: ...38 Figure 50 Model E157 Exploded View...
Page 47: ...39 9 3 MODEL E157 PARTS LIST 718702 282012 SV...
Page 48: ...40 Figure 51 Model E257 Exploded View...
Page 49: ...41 9 4 MODEL E257 PARTS LIST 718702...
Page 50: ...42 Figure 52 Model F257 Exploded View...
Page 51: ...43 9 5 MODEL F257 PARTS LIST 282022 SV...
Page 52: ...44...