10
Monitoring and diagnosis on the inverter
ID 441896.05
WE KEEP THINGS MOVING
Operation manual
64
Value:
0: Not synchronized;
1: Synchronized with AL event on this Sync Manager;
2: Synchronized with AL event Sync0;
3: Synchronized with AL event Sync1;
32: Synchronized with AL event of SM0;
33: Synchronized with AL event of SM1;
34: Synchronized with AL event of SM2;
35: Synchronized with AL event of SM3;
Index:
2108
hex
Subindex:
1
hex
A264.2 EtherCAT Sync Manager 2 Shift time
The parameter indicates the value of the shift time in ns for Sync Manager 2
(output process data) which was set by the controller on the inverter.
Information
Please note that the shift time is set exclusively by the controller. If you change
the parameter, your settings will have no effect.
Axis:
Global
Data type:
U32
Value:
0: Not synchronized;
1: Synchronized with AL event on this Sync Manager;
2: Synchronized with AL event Sync0;
3: Synchronized with AL event Sync1;
32: Synchronized with AL event of SM0;
33: Synchronized with AL event of SM1;
34: Synchronized with AL event of SM2;
35: Synchronized with AL event of SM3;
Index:
2108
hex
Subindex:
2
hex