The machine isn’t designed for employment in the explosive environment.
Operating the pump is forbidden to children and disabled person.
It is forbidden to employ the unit next to flammable liquids (gasoline, alcohol, etc.).
It is forbidden the employment in closed environments in presence of gasoline, LPG, methane fuelled
vehicles.
TRANSPORT AND UNPACKING
Due to its weight and dimensions, the unit can easily be transported by hand. Control that the package is
good conditions and verify that the unit isn’t damaged. Each failure must be noticed in 10 days from receiving
the machine.
For correct unpacking carefully follow these instructions:
1. Place the case on the ground following the indications on the package.
2. Carefully open the case, remove the machine and place it on the ground or on a steady surface.
3. Control that the machine and its accessories aren’t damaged.
4. Firstly, connecting the pump and the flow meter by flange kit (provided in the carton), then install the nozzle
holder to the bottom of the pump. Take out the elbow and screw it on the outlet of the flow meter. For details,
pleaser refer to “M Diagram”
5. Connect the coupling, see Fig. 1. Connecting Coupling 2 with the spout of the drum or tank. Joint Coupling
1 with the inlet of the pump. Install the suction hose on the thread of the Coupling 1. Then joint coupling 1 to
coupling 2, tighten by screwing the screw.
6. Screw the delivery hose on the fitting of the flow meter and of the filling gun.
NOTE: FOR ALL ABOVE CONNETION, SCREWED IT TIGHTLY WITHOUT ANY LEAKAGE!
Fig. 1
USE AND STARTING
STARTING
Once the hoses are sealed, the feeding cable is connected and the filling gun is in rest position, the machine
can be started. After placing the hose into the tank and the gun into the filling hole, start the pump, gradually
release the lever and start Diesel transfer. Once the filling is done release the control of the gun and switch
the pump off. When the pump isn’t in use disconnect it.
FLOW METER