2 of 7
PRELIMINARY INSPECTIONS
Before the power connection is done, verify the conductors aren’t live and general switches are off.
DISMANTLING AND DISPOSAL PROCEDURE
The metallic parts which the machine is mainly made of will be dismantled and sent to the steel mills. The
fuels in the tanks of the installation will be collected and sent to an authorized disposer. All plastic and
non-degradable material parts will be separately collected and sent to an authorized disposer or recycled.
SAFETY DEVICES
General Switch
It is placed on the motor body and allows the operator to set it on standby in a very short time. Once the
machine is stopped, the whole starting procedure can be repeated.
Harmful Functions
The noise from the machine is below 70 dB (A).
HARMFUL EMISSIONS
Steam emission is so reduced to result irrelevant.
FIRE PREVENTION
In case of fire never use water, but extinguishing powders charged with CO2 cat. A-B-C-D only, employing the
extinguishers placed next to the machine. Combustion of paints and plastic parts may produce toxic
emissions: use the normal precautions to be employed in case of fire (always refer to the security supervisor
of the place of installation).
FOR DC PUMP ONLY
ATTENTION
!
1. Extreme operating conditions with working cycles longer than 30 minutes can cause the motor temperature
to rise, thus damaging the motor itself.
2. Each 30-minute working cycle should always be followed by a 30-minute power-off cooling phase.
3. MAXIMUM BY-PASSING TIME: 3 MINUTES.
4. DO NOT RUN DRY OVER 30 SECONDS.
NOTICE: THE VISION IS BUILT PAYING MAXIMUM CARE TO USER’S AND MAINTENANCE
ENGINEER’S SECURITY.
C. TECHNICAL DATA
PUMP
MODEL
METER
MODEL
Flow Rate
ELECTRICAL POWER
Current Voltage(V) Frequency
10307000
Not Available
35/70LPM
9/18GPM
DC 12/24
\
10305610 Not
Available
56LPM/15GPM DC
12
\
10305611 Not
Available
56LPM/15GPM DC
24
\
10305619 Not
Available
56LPM/15GPM AC
230
50/60