STM DITI10305610 User Manual Download Page 1

  WARNING: Read carefully and understand all 

INSTRUCTIONS before operating. Failure to follow the safety 
rules and other basic safety precautions may result in serious 
personal injury. 

INTRODUCTION

The diesel transfer pump kit has been designed for the delivery of fuel from the drum & tanks in any situation. 

This manual, apart from giving all necessary information on ordinary maintenance and supporting engineers 

in failure detection and repair, should also give all the information’s needed to fully employ the capacity of 

the machine, as well as to the user’s needs.

   

INSTALLATION

Electric connection should be done on a CEI standard socket provided with switch (so it isn’t live when the
connection is done) according to L.46/90 prescriptions. 

DRUM PUMP KIT 

User’s Manual 

DITI10305610
DITI10305611
DITI10305619
DITI10307000
DITI10307207

1 of 7 

Summary of Contents for DITI10305610

Page 1: ...rt from giving all necessary information on ordinary maintenance and supporting engineers in failure detection and repair should also give all the information s needed to fully employ the capacity of...

Page 2: ...of fire never use water but extinguishing powders charged with CO2 cat A B C D only employing the extinguishers placed next to the machine Combustion of paints and plastic parts may produce toxic emi...

Page 3: ...arts SYSTEM DESCRIPTION Functional Description The diesel transfer system are hydraulic machine tools which feed with a given capacity volume of fluid in the time unit a collecting tank sucking the li...

Page 4: ...necting the pump and the flow meter by flange kit provided in the carton then install the nozzle holder to the bottom of the pump Take out the elbow and screw it on the outlet of the flow meter For de...

Page 5: ...e is no liquid inside Don t start the pump before connecting suction and delivery hoses 3 Once the gun is closed switch the motor pump off as soon as possible THE PUMP HAS TO WORK IN BY PASS CONDITION...

Page 6: ...ilter is clean MECHANICAL RISKS 1 Mechanical parts subject to wear The blades The bearing The rotor These parts should be replaced with original spare parts by qualified personal only or in authorized...

Page 7: ...scription Quantity Part No Component description Quantity 1 Outlet 1 8 O ring 2 2 Nozzle 1 9 flange 1 3 Bolt M6 2 10 Nut M8 2 4 Nozzle base 1 11 Bolt M8 2 5 Nut M6 2 12 pump 1 6 Mechanical meter Optio...