4

SpeedTech Lights, Inc © 2021 

ZX-180 TIR

COMBO SURFACE / UNDER MIRROR MOUNT

Wiring Diagram

Wire Color Function

 Red*

Positive

 Black*

Negative

 Yellow

Flash Pattern

  

  * Indicates a main power cable.

Specifications

Voltage

12 VDC

Amps

< 0.5

Optic

TIR

LED Count

6

Cable Length

1’

Flash Patterns

24

Wire Color Function

 Green

Steady Burn Override

 White

Sync (Max 8 Units)

 Blue

Alternating Sync Flash Pattern Programming

                                    NOTE: All cables except Negative c12 VDC.

Flash Pattern Synchronization

• 

Make sure all units that need to be synced together are powered On and flashing on the same pattern (see page 7 for flash pattern shortcuts).

• 

Connect the White cables of all units to each other.

• 

Connect the Yellow cables of all units to each other.

• 

Power all units Off and back On to verify Synchronization is complete.

Programming the Alternating Sync Flash Patterns

• 

Make sure all units that need to be synced together are powered On and flashing on the same pattern (see page 7 for flash pattern shortcuts).

• 

Divide the units into the 2 groups that you want to alternate with each other.

• 

Connect the White cables of all units to each other.

• 

Connect the Yellow cables of all units to each other.

• 

Connect all the Blue cables of Group A units together.

• 

Connect all the Blue cables of Group B units together.

• 

Contact all the connected Blue cables from Group A and apply it to +12VDC for about 3 seconds until half the unit steady burns.

• 

Contact all the connected Blue cables from Group B and apply it to +12VDC for about 5 seconds until the other half of the unit steady burns.

• 

Power all units Off and back On to verify the alternating functionality has been successfully programmed.

NOTE: Once the units have been programmed into Group A and Group B, they will keep those designations until reprogrammed.

Toggling Between Sync and Alternating Sync On The Fly

• 

Once you have successfully programmed your units into Group A and Group B following the alternating sync instructions, you can easily switch 

back and forth between alternating sync and synchronous flashing. 

• 

Once the units are in alternate sync mode, contact all the White cables of all the units that are connected together to +12VDC for 3 seconds. 

This will cease Group A & B alternating sync and will sync all units to flash together.

• 

To go back to alternating sync mode, contact all the White cables of all the units that are connected together to +1VDC for 1 second. 

NOTE: The units will remember their Group A or B designation forever until reprogrammed into a different group.