4
SpeedTech Lights, Inc © 2021
ZX-180 TIR
COMBO SURFACE / UNDER MIRROR MOUNT
Wiring Diagram
Wire Color Function
Red*
Positive
Black*
Negative
Yellow
Flash Pattern
* Indicates a main power cable.
Specifications
Voltage
12 VDC
Amps
< 0.5
Optic
TIR
LED Count
6
Cable Length
1’
Flash Patterns
24
Wire Color Function
Green
Steady Burn Override
White
Sync (Max 8 Units)
Blue
Alternating Sync Flash Pattern Programming
NOTE: All cables except Negative c12 VDC.
Flash Pattern Synchronization
•
Make sure all units that need to be synced together are powered On and flashing on the same pattern (see page 7 for flash pattern shortcuts).
•
Connect the White cables of all units to each other.
•
Connect the Yellow cables of all units to each other.
•
Power all units Off and back On to verify Synchronization is complete.
Programming the Alternating Sync Flash Patterns
•
Make sure all units that need to be synced together are powered On and flashing on the same pattern (see page 7 for flash pattern shortcuts).
•
Divide the units into the 2 groups that you want to alternate with each other.
•
Connect the White cables of all units to each other.
•
Connect the Yellow cables of all units to each other.
•
Connect all the Blue cables of Group A units together.
•
Connect all the Blue cables of Group B units together.
•
Contact all the connected Blue cables from Group A and apply it to +12VDC for about 3 seconds until half the unit steady burns.
•
Contact all the connected Blue cables from Group B and apply it to +12VDC for about 5 seconds until the other half of the unit steady burns.
•
Power all units Off and back On to verify the alternating functionality has been successfully programmed.
NOTE: Once the units have been programmed into Group A and Group B, they will keep those designations until reprogrammed.
Toggling Between Sync and Alternating Sync On The Fly
•
Once you have successfully programmed your units into Group A and Group B following the alternating sync instructions, you can easily switch
back and forth between alternating sync and synchronous flashing.
•
Once the units are in alternate sync mode, contact all the White cables of all the units that are connected together to +12VDC for 3 seconds.
This will cease Group A & B alternating sync and will sync all units to flash together.
•
To go back to alternating sync mode, contact all the White cables of all the units that are connected together to +1VDC for 1 second.
NOTE: The units will remember their Group A or B designation forever until reprogrammed into a different group.