4
SpeedTech Lights, Inc © 2019
FLARE 12
HIDEAWAY
Wiring Diagram
Wire Color Function
Red*
Positive
Black*
Negative
Yellow
Flash Pattern
* Indicates a main power cable.
Wire Color Function
Green
Steady Burn Override
White
Sync
Blue
Alternating Sync Programming
NOTE: All cables except Negative and Sync c12 VDC.
Specifications
Voltage
12 VDC
Amps
< 1.0
Optic
Dome Lens
LED Count
12
Cable Length
1’
Flash Patterns
34
Flash Pattern Synchronization
•
Make sure all units that need to be synced together are powered On and flashing on the same pattern.
•
Connect the White cables of all units to each other.
•
Connect the Yellow cables of all units and c12 VDC to cycle all units to the next pattern.
•
Power all units Off and back On to complete the Sync process.
Flash Pattern Alternating Synchronization
•
Make sure all units that need to be synced together are powered On and flashing on the same pattern.
•
Connect the White cables of all units to each other.
•
Divide the units into 2 groups and connect all the Blue cables of the first group together.
•
Connect all the Blue cables of the second group together.
•
Take all the Blue cables from the first group and c12 VDC for 3 seconds until all first group units are steady burn. Only half
of each unit will light up steady burn.
•
Take all the Blue cables from the second group and c12 VDC for 5 seconds until all second group units turn off.
•
Power all units Off and back On to complete the Alternating Sync process.
•
NOTE: All programming of both groups must be completed prior to the steady burn portions ceasing.