2.4 – The Swift GUI Touch Screen

The Swift GUI is implemented on a touch screen control  
panel on the front of the cabinet. Its capabilities are described 
in detail later. General features of the control panel are:

• 

Set freezer control, alarm and communications parameters

• 

Provide password protected access to parameter changes

• 

Display freezer status

• 

Display temperature graph and event log

• 

Display diagnostic and service information

• 

Display freezer identification information 

Values for the following SU105U parameters are viewed and modified through  
the touch screen. 

Modifiable Values

Accessible Values

Temperature set point

Current freezer interior temperature

Under temperature limit

Temperature history chart

Over temperature limit

Interior vs. FPSE temperatures

Over temperature delay after door opening

Alarm status

Audible alarm silence interval

Swift GUI firmware event log

External contact delay upon alarm

 “About” screen (general information)

Door open alarm delay

Service contact information

Door defroster status

Diagnostics screen

Door auto-defrost status

Manual defrost time

Password Identification Number (PIN) status

Current date

Current time

RTD calibration adjustments

2. Features

Summary of Contents for SU105U

Page 1: ...Operating Manual 03 2012 1 SU105U 86 C Ultra Low Storage 6000 Poston Rd Athens Ohio 45701 USA t 740 274 7900 855 274 7900 f 740 274 7901 www stirlingultracold com...

Page 2: ...2 03 2012 1 Operating Manual SU105U 86 C Ultra Low Storage...

Page 3: ...cord Battery Power Switch on the battery power located on the left of the Recessed Electrical Panel This is essential if monitoring is required in the event of a power failure Change Set Point Tap Ho...

Page 4: ...4 03 2012 1 Operating Manual SU105U 86 C Ultra Low Storage...

Page 5: ...Free Piston Stirling Engine FPSE 8 2 2 Cabinet Design Features 8 2 3 Temperature Monitoring Features 8 2 4 The Swift GUI Touch Screen 9 2 5 Pictorial Tour 10 2 6 Included Items 11 2 7 Options 11 2 7...

Page 6: ...rformance of the freezer is controlled by electronic logic that is programmed through a touch screen interface termed the Swift Graphical User Interface GUI This operating manual describes use of the...

Page 7: ...ganization of this Operating Manual This manual is organized as follows Unpacking and installation Set up Operation Transporting and moving Please note that precautions and safety instructions are par...

Page 8: ...izes water or ice deposition on the gasket interface 2 3 Temperature Monitoring Features Two resistance temperature detectors RTDs measure the internal cabinet tempera ture of the SU105U One provides...

Page 9: ...alues for the following SU105U parameters are viewed and modified through the touch screen Modifiable Values Accessible Values Temperature set point Current freezer interior temperature Under temperat...

Page 10: ...d Stainless Steel Shelf 5 Air Inlet 6 Access Port For thermocouple wires purge gas etc 7 Air Outlet 8 Recessed Electrical Panel A AC Power Connector B AC Power Switch C External Alarm Terminal Strip D...

Page 11: ...ews 2 7 1 Adapter Installation Procedure 1 Remove rear casters from both freezers Install adjustable leveling feet 2 Move 2nd unit over the top of 1st unit sitting on floor Note the net weight is abou...

Page 12: ...ow Do not disassemble modify or repair There are no user serviceable parts inside the freezer unit Do not immerse in water pour water on the unit or operate where water may drip or fall on the unit Op...

Page 13: ...emperatures are not spilled onto skin or clothing Ultra low temperatures may adversely impact freezer contents Do not put ice or liquid water directly in the freezer box always use suitable containers...

Page 14: ...ectrical connections to the panel on the back of the freezer 4 Ingress to the access port see Page 10 is required during normal operation 5 The freezer must be installed on a nominally level surface a...

Page 15: ...aches its operating temperature and its door is opened and closed the partial vacuum created when warm air is admitted then cooled will prevent reopening of the door until the pressure is equalized A...

Page 16: ...l panel 2 Managing the freezer contents 3 Cleaning and defrosting the freezer 4 Calibrating the freezer s display RTD Specification of responsibilities for each of the above components of freezer oper...

Page 17: ...ntering the date time and temperature set point are the most essential actions Unless temperature limits are set manually the software calculates default values appropriate for the temperature set poi...

Page 18: ...ess and DHCP server addresses Date Time Setup display and change system date and time Door Defrost enable disable automatic door defrosting and or set a manual defrost time and initiate manual defrost...

Page 19: ...and those names are shown in bold Access to certain screens requires entry of the system PIN via a numeric keypad screen this entry is shown as the PIN button tap Guide to Basic GUI Functions ON OFF S...

Page 20: ...3 Swift Graphical User Interface GUI Instructions 1 Start Screen Turn On Freezer and Battery Power Stirling Ultracold splash screen will appear for 3 seconds 2 Home Screen The Home screen will be dis...

Page 21: ...events Tap the Chart History button to track the box air temperature over the last 12 hours 24 hours or 7 days Tap the About button for freezer information including build and service and calibration...

Page 22: ...stem date and time Tap the Door Defrost button to setup auto defrost or to start a manual defrost Tap PIN to change or disable PIN Tap the Back button to return to the Setup Screen Tap the Home button...

Page 23: ...elay delay between audible alarm and remote alarm Door Delay period of time that the door can be open before sounding an alarm Tap the Save button to save configurations Tap the Back button to return...

Page 24: ...tap Enter To disable PIN leave the Enter New PIN field blank and tap Enter 9 Door Defrost Heater When set to Auto Defrost the door defrost heater will cycle 15 minutes ON and 20 minutes OFF unless oth...

Page 25: ...ges Tap the Back button to return to the Setup Screen Tap the Home button to take you back to the Home Screen 12 Chart History Chart History will display the internal box air temperature for the last...

Page 26: ...Hours Set Point and Date Tap the Service button to look at freezer parameters such as temperatures and engine voltage current and power Tap the Back button to return to the Setup Screen Tap the Home...

Page 27: ...ure alarms Tap the Diag button to get to the system diagnostics screen Tap the SVC Contact button find dealer information Tap the RTD Calibr button to calibrate the RTD Note PIN required to calibrate...

Page 28: ...email and web address for distributor Tap the Back button to return to the Setup Screen Tap the Home button to take you back to the Home Screen 17 Diagnostics Diagnostic Screen provides system health...

Page 29: ...repancies between the Display RTD and a user provided standard Tap RTD Select until the desired RTD is selected then use the and buttons to adjust the offset Tap the Calib button to save changes Tap t...

Page 30: ...ement that does not block the access port interfere with the door gasket or prevent the door from closing completely The Safety Precautions section of this Operating Manual is especially pertinent to...

Page 31: ...save changes 6 Transporting Moving and Storage To move the freezer to another location or temporarily place it into storage perform the following steps Transfer the contents of the freezer to alterna...

Page 32: ...ting Temperature 5 C to 35 C at RH 65 Warehouse Storage Temperature 5 C to 60 C at RH 65 Operational Environment This ultra low temperature freezer is designed for use in a normal laboratory environme...

Page 33: ...num Gray Powder coated Hinges Steel White Powder coated LCD Bezel Polycarbonate Gray Natural SIDE 27 9 709mm 23 9 606mm 21 0 533 mm 8 0 203 mm 4 5 114 mm FRONT 33 5 851 mm 32 5 826 mm 4 5 114 mm 4 3 1...

Page 34: ...e Inadequate air circulation Remove airflow obstructions Inadequate power Assure that the wall plug is firmly seated Improper environment Remove freezer from direct sunlight hot room etc Check that fr...

Page 35: ...for storage of frozen product For best results Always operate your freezer at full capacity with real or simulated product to increase the thermal mass displace air and maintain optimal stability Alwa...

Page 36: ...zation for a service company to diagnose the problem must be approved by Global Cooling Inc Global Cooling Inc will not be responsible for charges incurred for service calls made by a third party prio...

Page 37: ...urchased hereunder free and clear of all liens and encumbrances Global Cooling further warrants all products to be free from defects in materials under normal use and service for a period of TWO YEARS...

Page 38: ...38 03 2012 1 Operating Manual SU105U 86 C Ultra Low Storage...

Page 39: ...39 t 855 274 7900 www stirlingultracold com 10 CE Documentation 13 CE Documentation...

Page 40: ...tracold com 2012 Stirling Ultracold Global Cooling Inc All Rights Reserved HUMM technology is manufactured under U S and International patents Stirling Ultracold Shuttle HUMM and Swift are trademarks...

Reviews: