background image

State: 04.12.2020 p. 3

Mounting instructions for multiplay „ascendo 1B“ Robinia

Item-No. 51 7502 601

©  stilum GmbH, Gewerbegebiet Larsheck, D-56271 Kleinmaischeid  •  Tel. +49 (0) 2689 92790-0  •  All rights and product modifications reserved.

7190

400

1717

2663

1992

 450 

 2921 

 3371 

A

A

424

2070

2557

600

400

500

1000

910

1750

1690

3439

 1992 

 550 

3538

600

7505

 875 

  600 

A-A

3180

 400 

 450 

OHNE SCHRIFTLICHE ZUSTIMMUNG DER KAISER GMBH DARF DIESE 

TECHNISCHE UNTERLAGE WEDER VERVIELFÄLTIGT, NOCH DRITTEN MITGETEILT ODER 

ZUGÄNGLICH GEMACHT WERDEN, NOCH IN SONSTIGER WEISE MISSBRÄEUCHLICH VER- 

WENDET WERDEN. ZUWIDERHANDLUNGEN WERDEN URHEBERRECHTLICH VERFOLGT.

1

 

ascendo 1B

Benennung

Gepr.

Blatt

Datum

Projekt

Gez.

Zeichnungsnummer

1:50

A3

Name

Name

Fundament

1026-00-00

Maßstab

Mattheis

03.05.17

 

 

Gewerbegebiet Larsheck

56271 Kleinmaischeid

Deutschland

Beton

concrete

gewachsenes Erdreich

natural ground

Legende

stoßdämpfender Boden

shock-absorbing floor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
ES

09.09.20

stoßdämpfender Boden

A

Datum

Änderung

Rev

7190

400

1717

2663

1992

 450 

 2921 

 3371 

A

A

424

2070

2557

600

400

500

1000

910

1750

1690

3439

 1992 

 550 

3538

600

7505

 875 

  600 

A-A

3180

 400 

 450 

OHNE SCHRIFTLICHE ZUSTIMMUNG DER KAISER GMBH DARF DIESE 

TECHNISCHE UNTERLAGE WEDER VERVIELFÄLTIGT, NOCH DRITTEN MITGETEILT ODER 

ZUGÄNGLICH GEMACHT WERDEN, NOCH IN SONSTIGER WEISE MISSBRÄEUCHLICH VER- 

WENDET WERDEN. ZUWIDERHANDLUNGEN WERDEN URHEBERRECHTLICH VERFOLGT.

1

 

ascendo 1B

Benennung

Gepr.

Blatt

Datum

Projekt

Gez.

Zeichnungsnummer

1:50

A3

Name

Name

Fundament

1026-00-00

Maßstab

Mattheis

03.05.17

 

 

Gewerbegebiet Larsheck

56271 Kleinmaischeid

Deutschland

Beton

concrete

gewachsenes Erdreich

natural ground

Legende

stoßdämpfender Boden

shock-absorbing floor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
ES

09.09.20

stoßdämpfender Boden

A

Datum

Änderung

Rev

Diagram 3: Foundation plan

Summary of Contents for multiplay ascendo 1B Robinia

Page 1: ...B Robinia Item No 51 7502 601 stilum GmbH Gewerbegebiet Larsheck D 56271 Kleinmaischeid Tel 49 0 2689 92790 0 All rights and product modifications reserved fireman s pole tower climbing slant slide swing rail Diagram 1 Overall view of the play equipment post post shoe ...

Page 2: ...ent 5 After a setting period of 10 14 days depending on weather conditions and foundation size fill up and compress the holes between the foundation and the foundation hole with excavation 6 Clean the surface of the foundations and start with the installation of the play equipment Reinforcement plan Concrete foundation with reinforcement Foundation BSt 500S Stirrups Ø 8 mm lengthwise and cross Con...

Page 3: ... 2070 2557 600 400 500 1000 910 1750 1690 3439 1992 550 3538 600 7505 875 600 A A 3180 400 450 ascendo 1B Benennung Gepr Datum Projekt Gez Name Fundament Maßstab Mattheis 03 05 17 Beton concrete Legende stoßdämpfender Boden shock absorbing floor 400 1717 2663 450 2921 3371 A 424 2070 2557 600 400 910 1750 3439 550 3538 600 7505 875 600 A A Beton concrete gewachsenes Erdreich natural ground Legende...

Page 4: ...with the included heavy duty dowels OHNE SCHRIFTLICHE ZUSTIMMUNG DER CONRADI KAISER GMBH DARF DIESE TECHNISCHE UNTERLAGE WEDER VERVIELFÄLTIGT NOCH DRITTEN MITGETEILT ODER ZUGÄNGLICH GEMACHT WERDEN NOCH IN SONSTIGER WEISE MISSBRÄEUCHLICH VER WENDET WERDEN ZUWIDERHANDLUNGEN WERDEN URHEBERRECHTLICH VERFOLGT 1 ascendo robinie Benennung Gepr Blatt Datum Projekt Gez Zeichnungsnummer 1 20 A3 Name Feuerwe...

Page 5: ...o 51 7502 601 stilum GmbH Gewerbegebiet Larsheck D 56271 Kleinmaischeid Tel 49 0 2689 92790 0 All rights and product modifications reserved Diagram 5a connection firemans pole Diagram 5c connection climbing slant Diagram 5d connection swing B D E C F H J J Diagram 5b connection slide ...

Page 6: ...es STAINLESS STEEL NOTE Play equipment which contain components made of stainless steel should not come with normal steel parts in contact Those steel parts may rub off and leave small steel particles in combination with moisture brown rust stains MAINTENANCE If such corrosion occur on stainless steel parts they are fine to remove with an abrasive 240 grit Please take care when transporting and se...

Page 7: ...mpaired See EN 1176 Bbl 1 2019 01 4 2 7 6 Dry cracks in wood elements as a conse quence of weather conditions are not to be considered as dangerous openings in terms of the standard due to the fact that the shape of the cracks tapering towards the inside makes it almost impossible for fingers to get trapped in them MAINTENANCE To ensure a long life of stilum playground equipment wooden surfaces sh...

Reviews: