WARNING
No smoking and no naked lights and fires when filling
LPG tanks.
CAUTION
While removing the filling pistol a small quantity of
gas streams out. As this can cause frostbite, always
put on protective gloves.
NOTE
We recommend to top up gas before begin-
ning work, as long as the truck is still cold. If
temperatures differ much between the supply
tank in the open and the tank on the truck it
may be possible that the supply pressure of
the pump is not sufficient to fill the tank com-
pletely.
WARNING
When LP-gas leaks out, there is an immediate dan-
ger of explosion, resulting in the risk of burns.
–
Stop the engine and, if needed, the heater
and combustionchamber.
–
Put on protective gloves.
–
Close the shutoff valve (1).
–
Remove the cap from the filler valve (4).
–
Open the shutoff valve (3)
–
Check the filling pistol thread for cleanli-
ness.
–
Connect the filling pistol to the filler valve
(4).
–
Open the main shutoff valve of the LPG sta-
tion and operate the pump motor or filling
pistol until the valve installed in the tank
stops the filling.
Capacity : approx. 35,0 litres
–
Release the filling pistol control immediately
and terminate the filling procedure.
–
Turn off the pump motor and the main shut-
off valve at the LPG station.
Use and Operation
4
Fill the LPG tank*
62
60108011601 EN - 04/2020
Summary of Contents for RCG25
Page 2: ......
Page 4: ......
Page 10: ......
Page 11: ...1 Introduction ...
Page 19: ...2 Safety ...
Page 41: ...3 Information about the truck ...
Page 52: ...Information about the truck 3 Location of the decals 42 60108011601 EN 04 2020 ...
Page 53: ...4 Use and Operation ...
Page 120: ...Use and Operation 4 Decommissioning 110 60108011601 EN 04 2020 ...
Page 121: ...5 Maintenance ...
Page 156: ...Maintenance 5 Maintenance service 146 60108011601 EN 04 2020 ...
Page 157: ...6 Technical datasheet ...
Page 158: ...Dimensions Technical datasheet 6 Dimensions 148 60108011601 EN 04 2020 ...
Page 168: ...Technical datasheet 6 Mast specifications 158 60108011601 EN 04 2020 ...
Page 172: ......
Page 173: ......
Page 174: ...STILL GmbH 60108011601 EN 04 2020 ...
Page 176: ......
Page 177: ...7 Diagrams ...
Page 179: ...Hydraulic diagram Diagrams 7 Hydraulic diagram 169 60108011601 EN 04 2020 ...
Page 180: ...Diagrams 7 Hydraulic diagram 170 60108011601 EN 04 2020 ...
Page 181: ......
Page 182: ...STILL GmbH 60108011601 EN 04 2020 ...