Maintenance
6
Maintenance after 12 months
Maintenance after 12 months
Work that must also be carried out
– Carry out servicing work; see the chapter
entitled "Servicing".
– Carry out maintenance after three months;
see the chapter entitled "Maintenance after
three months".
– Carry out maintenance after six months;
see the chapter entitled "Maintenance after
six months".
Changing the hydraulic oil
WARNING
Consumables are toxic!
– Note safety regulations for working
with hydraulic oil, see ⇒ Chap-
HPT 10 XE
– Jack up the industrial truck, see ⇒ Chap-
HPT10_044
1
2
– Place a suitable collection container under
drain plug (1).
– Unscrew drain plug (1) and allow all the oil
to drain off.
ENVIRONMENT NOTE
•
Dispose of used oil according to applicable
regulations.
– Change the sealing ring (2).
– Tighten the drain plug to 30 Nm.
– Top up with hydraulic oil of the correspond-
ing specification, see ⇒ Chapter "Mainte-
– Actuate the lifting system several times.
– Check the oil level and top up as necessary.
50988046052 EN - 10/2018
77
Summary of Contents for HPT 10 XE
Page 2: ......
Page 4: ......
Page 9: ...1 Foreword ...
Page 17: ...2 Introduction ...
Page 25: ...3 Safety ...
Page 36: ...3 Safety Safety regulations for handling consumables 28 50988046052 EN 10 2018 ...
Page 37: ...4 Overviews ...
Page 43: ...5 Operation ...
Page 64: ...5 Operation Cleaning 56 50988046052 EN 10 2018 ...
Page 65: ...6 Maintenance ...
Page 82: ...6 Maintenance Maintenance after 3 months 74 50988046052 EN 10 2018 ...
Page 88: ...6 Maintenance Maintenance after 12 months 80 50988046052 EN 10 2018 ...
Page 89: ...7 Technical data ...
Page 94: ...7 Technical data Technical datasheet 86 50988046052 EN 10 2018 ...
Page 98: ......
Page 99: ......
Page 100: ...STILL GmbH 50988046052 EN 10 2018 ...