Display of normal running
On the occurrence of a failure, the corre-
sponding icons will give a combined blink:
The error codes and types are shown as fol-
lows:
Refrigerator
Error
Code
Error Description
Display
E1
Temperature sen-
sor of Refrigerator
room fail
Icon “ ” & Icon “
2
”
shine at same time
E5
Defrosting sensor
of Refrigerator
room fail
Icon “ ” & Icon “
3
”
shine at same time
E6
Communication
error
Icon “ ” & Icon “
4
”
shine at same time
E7
Ambient tempera-
ture sensor fail
Icon “ ” & Icon “
4
”
shine at same time
E10
Sticking problem
with Button
Icon “
2
” & Icon “
3
”
shine at same time
Fridge
Error
Code
Error Description
Display
E1
Temperature
sensor of Freezer
room fail
Icon “ ” & Icon
“
-24
” shine at same
time
E5
Defrosting sensor
of Freezer room
fail
Icon “ ” & Icon
“
-22
” shine at same
time
E6
Communication
error
Icon “ ” & Icon
“
-20
” shine at same
time
E7
Ambient tempera-
ture sensor fail
Icon “ ” & Icon
“
-20
” shine at same
time
E10
Sticking problem
with Button
Icon “
-24
” & Icon “
-22
”
shine at same time
If no failure, the screen displays the setting
temperature of the refrigerator room.
Fridge/Freezer conversion
Press the button for 3 seconds to
achieve Fridge/Freezer conversion, the cor-
responding temperature icons shine.
Temperature setting
The temperature setting will be changed
once you press button .Then, the re-
frigerator will run according to the new tem-
perature setting after 15s
Quick cooling mode
Enter: under refrigerator mode,press the
button( ) until the icon lighten.
During quick cooling mode, the refrigerator
runs according to the temperatures set at
2
°C,
and it will exit this mode automatically
after running for 150 minutes or tempera-
ture setting or mode setting.
Quick freezing mode
Enter: under freezer mode, press the button
( ) until the icon lighten.
During mode, quick freeze automatically
after running for 24 hours or temperature
setting or mode setting. The freezer runs
according to the temperature set at -24
°C
,it
will exit this mode.
Max. freezing capacity
• Information about the max. freezing ca-
pacity within 24 hours can be found on the
rating plate.
Prerequisites for max. freezing capacity
• Switch on super freezing before placing
fresh products in the compartment (see
chapter entitled “Super freezing”).
• Removing the fittings
• The food can be stacked directly on the
shelves and in the bottom of the freezer
compartment.
Note
• Do not cover the ventilation slots on the
rear panel with frozen food.
• Freeze large quantities of food preferably
in the very top compartment where food
freezes particularly quickly and therefore
also gently.
Freezing and storing food
Purchasing frozen food
• Packaging must not be damaged.
• Use by the “use by” date.
• Temperature in the supermarket freezer
must be -18 °C or lower.
• If possible, transport deep-frozen food in