![Stihl FS 240 Service Manual Download Page 47](http://html1.mh-extra.com/html/stihl/fs-240/fs-240_service-manual_1378617047.webp)
46
FS 240 C, FS 260 C, FS 360 C, FS 410 C, FS 460 C-M
:
Pull the lug (1) of the short circuit
wire (2) out of the mount
– Connect ohmmeter to
ground and the lug of the short
circuit wire
– For versions with control handle
for loop handle, move slide
control to position
STOP-0
and
hold it there
– For versions with control handle
for bike handle, press and hold
lever for stop function
The resistance measured must be
approx. 0
Ω
. If it is much higher, the
reason is a break in the wire and the
throttle cable must be replaced,
– Release slide control or lever for
stop function = position "
F
"
The resistance measured must be
infinitely high, otherwise replace the
throttle cable,
6.6,
The ground wire must also be
tested for contact and continuity.
If the ground wire is damaged, the
throttle cable must also be replaced.
1
2
5904RA242 TG
– If no fault can be found, test the
ignition system in accordance
with flow chart,
– Reassemble parts in reverse
order
6.6.2
Short circuit wire
on engine,
removal and installation
– Remove shroud,
– Unplug the spark plug boot
– Remove drive tube assembly,
1-point antivibration system,
12.1, 4-point antivibration
system,
– Remove machine cover,
:
Remove screw (1) and pull
lead (2) of the ignition module out
of the guides (arrows)
:
Remove short circuit wire (1)
from the guides (arrows)
1
2
5904RA097 TG
1
5904RA098 TG
The blade receptacle is
permanently connected to the
connector tag and cannot be pulled
off.
:
Remove screw (1)
:
Remove ground wire (2) from the
guides (arrows)
:
Remove screw (1)
:
Lift up cable holder (2) slightly,
pull out protective tube (3) by the
tab (4) and out of the
guide (arrow)
:
Pull throttle cable (1) out of the
mount (arrow) and unhook it from
the lever (2)
1
5904RA099 TG
2
5904RA100 TG
1
3
2
4
1
2
5904RA101 TG