background image

► Push battery (4) as far as it will go into the belt

bag (5).

A short beep will sound.

► Secure battery (4) with the Velcro® fasten‐

ing (6).

6.7.2

Adjusting the Connecting Cable

The connecting cable can be fitted and adjusted

to suit the user’s size and the application.

2

0000-GXX-3418-A0

1

3

The length of the connecting cable can be adjus‐

ted by making a loop (1) and securing it to the

belt bag (3) with the fastener (2).

► Arrange the connecting cable so that it is as

short as possible without hindering your work.

7

Inserting and Removing

Connecting Cable Plug

7.1

Inserting the Connecting Cable

Plug

0000-GXX-4434-A0

2

1

► Hold connecting cable plug (2) so that the

arrow on its side lines up with the arrow on the

socket (1).

► Insert the connecting cable plug (2) in the

socket (1).

The plug (2) engages in position.

7.2

Removing the Connecting

Cable Plug

0000-GXX-4435-A0

2

1

► Grip the connecting cable plug (2) with your

hand.

► Pull the plug (2) out of the socket (1).

8

Switching the Blower

On/Off

8.1

Switching On the Blower

► Hold the blower firmly with your right hand on

the control handle – wrap your thumb around

the handle.

3

1

2

0000-GXX-B527-A0 

► Press the trigger lockout (1) with your hand

and keep it pressed.

► Push release slide (2) in direction of arrow

with your thumb and allow it to spring back.

The LEDs illuminate to indicate the power

level at last use.

► Press the trigger (3) with your index finger and

keep depressed.

The blower accelerates and air flows out of the

nozzle.

The further the trigger switch (3) is depressed,

the more air flows out of the nozzle.
The blower can also be switched on by first

pressing the release slide (2) and pressing the

trigger lockout (1) within 5 seconds (as long as

the LEDs are flashing). The trigger (3) is now

unlocked and the blower is ready for use.
The LEDs continue flashing for 5 seconds after

the trigger (3) and trigger lockout (1) are

released after switch-on. As long as the LEDs

are flashing, the blower can be switched on

7 Inserting and Removing Connecting Cable Plug

English

0458-812-0121-B

11

Summary of Contents for BGA 200

Page 1: ...BGA 200 2 16 Instruction Manual...

Page 2: ...us and hope you will enjoy working with your STIHL product Dr Nikolas Stihl IMPORTANT READ BEFORE USING AND KEEP IN A SAFE PLACE FOR REFERENCE 2 Guide to Using this Manual 2 1 Applicable Documents Th...

Page 3: ...r a STIHL AR battery 4 Deluxe Carrying System Serves to carry blower on STIHL AR L or AR battery 5 STIHL AR Battery Supplies power to the blower 6 Hip Pad Serves to secure blower to STIHL AR battery o...

Page 4: ...ion manual If you pass the blower on to another per son Always give them the instruction man ual Make sure the user meets the following requirements The user must be rested The user must be in good ph...

Page 5: ...is dirty Clean the blower Do not modify the blower Exception Mounting a nozzle approved for this blower model If the controls do not function properly Do not work with the blower Fit original STIHL ac...

Page 6: ...age the blower If the blower is not cleaned as described in this instruction manual components may no lon ger function properly or safety devices may be rendered inoperative They may cause serious inj...

Page 7: ...A1 Line up mark 3 with mark 4 Fit the slide 2 Pull the slide 2 up in opposite direction to arrow The slide 2 engages with a click Set slide 2 to same position on left and right shoulder straps 6 2 2...

Page 8: ...kplate with the fasteners 2 0000 GXX 2803 A0 4 3 The length of the connecting cable can be adjus ted by making a loop on the backplate 3 or at one side 4 Fit the connecting cable so that it is as shor...

Page 9: ...0000 GXX B495 A1 Attach the blower to the deluxe carrying sys tem The height of the plate 8 is correct when the user s arm is slightly bent while guiding the blower by the front gripping point 9 6 5 U...

Page 10: ...ust the strap 1 so that the carabiner 2 is about a hand s width below your right hip 6 6 Fitting the Hip Pad The hip pad serves to secure the blower to the STIHL AR L or AR battery or the carrying sys...

Page 11: ...ull the plug 2 out of the socket 1 8 Switching the Blower On Off 8 1 Switching On the Blower Hold the blower firmly with your right hand on the control handle wrap your thumb around the handle 3 1 2 0...

Page 12: ...flash red Pull con necting cable plug out of the socket and con tact your STIHL dealer for assistance There is a malfunction in the blower Release the trigger No air flows from the nozzle If air conti...

Page 13: ...ou release the trigger 1 The previously selected power level is restored 10 5 Blow Sweeping 0000 GXX 4440 A0 Point the nozzle at the ground Walk slowly and steadily forwards 11 After Finishing Work 11...

Page 14: ...If 3 LEDs continue to flash red Do not use the blower and contact your STIHL dealer for assistance 3 LEDs light up red The blower is too warm Pull the connecting cable plug out of the socket Allow th...

Page 15: ...ay be used to compare electric power tools Depending on the type of usage the vibrations that actually occur may differ from the values quoted The vibration values quoted may be used for an initial as...

Page 16: ...tion of Con formity 21 1 STIHL BGA 200 Blower ANDREAS STIHL AG Co KG Badstra e 115 D 71336 Waiblingen Germany declare under our sole responsibility that Type Cordless blower Manufacturer s brand STIHL...

Page 17: ...21 UKCA Declaration of Conformity English 0458 812 0121 B 17...

Page 18: ...English 21 UKCA Declaration of Conformity 18 0458 812 0121 B...

Page 19: ...21 UKCA Declaration of Conformity English 0458 812 0121 B 19...

Page 20: ...www stihl com 04588120121B 04588120121B 0458 812 0121 B 0458 812 0121 B...

Reviews: