ADG 2
English
5
N
Push the battery (1) into the
analyzer (2) until you feel noticeable
resistance – then push it as far as
stop.
The test continues automatically when
the battery is inserted. If the test does
not continue, the reason may be:
–
No contact between battery and
analyzer – remove the battery and
refit it.
–
Fault in battery – test with STIHL
ADG 1 battery analyzer if
necessary.
If the battery's state of charge is too low,
the analyzer's display shows:
N
Use a properly charged battery.
Insert adapter
Inserting the adapter connects the
cordless power tool to the battery. The
cordless power tool is ready for
operation.
The cordless power tool's motor starts to
run during the test. Before starting the
test, always take precautions to
eliminate the risk of accidents and injury
from contact with the power tool's
attachment.
The following instructions appear on the
display:
N
Eliminate risk from tool – see
Technical Information bulletins on
ADG 2 analyzer and the cordless
power tool being tested.
N
Press the lower button to confirm.
N
Insert adapter (1) in power tool's
battery compartment – the adapter
slides into position – press it home
until it engages audibly. The
adapter must be flush with the top of
the housing.
N
Press the lower button to confirm.
N
Press the lower button to confirm.
Data transfer
The cordless power tool and analyzer
communicate with each other. The
analyzer can test the cordless power
tool only if this data exchange functions.
N
Switch on the cordless power tool –
see power tool's instruction manual.
If there is no data exchange between the
power tool and the analyzer, the
problem is in the connection to the
power tool – refer to Technical
Information bulletins on ADG 2 analyzer
and the power tool concerned.
N
Switch on the cordless power tool
again – the test starts.
Checking operation of controls
The controls differ according to the
cordless power tool being tested. The
following procedure describes the
trigger switch on the FSA 85 cordless
trimmer as an example.
The display always shows the current
position of the control:
N
Operate trigger switch
State of charge too low
2
7BA002 KN
Eliminate risk from
tool
Insert adapter
CAUTION!
Motor may start
1
7BA003 KN
Switch on the saw.
Data transfer
Switch on unit again
Operate trigger switch
OFF 0%