background image

OpEraTiON 

 

General information

www.stiebel-eltron.com 

SNE 5 t ECO GB| 

3

OpEraTiON

1.  General information

The chapters "Special information" and "Operation" are intended 

for both users and qualified contractors.
The chapter "Installation" is intended for qualified contractors.

 

Note

Read these instructions carefully before using the appli-

ance and retain them for future reference.

Pass on the instructions to a new user if required.

1.1  Safety instructions

1.1.1  Structure of safety instructions

 

KEYWORD Type of risk

Here, possible consequences are listed that may result 

from failure to observe the safety instructions.

f

f

Steps to prevent the risk are listed.

1.1.2  Symbols, type of risk

Symbol

Type of risk

 

 

Injury 

 

 

 

Electrocution 

 

 

 

Burns

(burns, scalding) 

1.1.3  Keywords

KEYWOrD

meaning

DANGER 

Failure to observe this information will result in serious 

injury or death.

WARNING 

Failure to observe this information may result in serious 

injury or death.

CAUTION 

Failure to observe this information may result in non-seri-

ous or minor injury.

1.2  Other symbols in this documentation

 

Note

General information is identified by the adjacent symbol.

f

f

Read these texts carefully.

Symbol

meaning

 

 

Material losses

(appliance damage, consequential losses and environmen-

tal pollution)

 

 

Appliance disposal 

 

f

f

This symbol indicates that you have to do something. The ac-

tion you need to take is described step by step.

1.3  Units of measurement

 

Note

All measurements are given in mm unless stated oth-

erwise.

2.  Safety

2.1  Intended use

This open vented (non-pressurised) appliance is designed for heat-

ing domestic hot water. The appliance can supply one draw-off 

point.
The appliance is intended for domestic use. It can be used safely 

by untrained persons. The appliance can also be used in non-do-

mestic environments, e.g. in small businesses, as long as it is 

used in the same way.
Any other use beyond that described shall be deemed inappro-

priate. Observation of these instructions and of the instructions 

for any accessories used is also part of the correct use of this 

appliance.

Summary of Contents for SNE 5 t ECO

Page 1: ...OPERATION AND INSTALLATION Open vented non pressurised small water heater SNE 5 t ECO GB...

Page 2: ...stallation Maintenance Draining the appliance SPECIAL INFORMATION OPERATION 1 General information 3 1 1 Safety instructions 3 1 2 Other symbols in this documentation 3 1 3 Units of measurement 3 2 Sa...

Page 3: ...njury or death CAUTION Failure to observe this information may result in non seri ous or minor injury 1 2 Other symbols in this documentation Note General information is identified by the adjacent sym...

Page 4: ...content at the set temperature in line with the pre selected oper ating mode The appliance may only be installed with taps for open vented non pressurised water heaters see chapter Installation Appli...

Page 5: ...lation Troubleshooting Fault list Call your qualified contractor Green LED flashes The appliance was disconnected from the power sup ply for a long time approx 8 hours Reset the day and time 3 1 3 Dis...

Page 6: ...symbol appears you can change the setting of the menu item with and Press OK to save the setting To exit the standard menu press Menu The standard display appears Note During initial start up and fol...

Page 7: ...d weekly To configure a comfort phase in time program Pro3 proceed as follows f f In the configuration menu use and to call up time program Pro3 f f Press OK The display shows 3 f f Press OK The day o...

Page 8: ...s Activating parameter P5 resets the appliance to the factory setting 5 Cleaning care and maintenance f f Never use abrasive or corrosive cleaning agents A damp cloth is sufficient for cleaning the ap...

Page 9: ...INSTALLATION TEMPLATE...

Page 10: ......

Page 11: ...79 mm 140 mm 407mm 263mm 407mm 263mm D0000071802...

Page 12: ...NOTES...

Page 13: ...wing are delivered with the appliance Wall mounting bracket 8 2 Accessories 8 2 1 Required accessories The following taps are available as accessories for open vented operation Mixer taps WST WUT Mono...

Page 14: ...with a fully opened tap see chapter Installation Specification Data table Match up the colour coding on the tap water connections and the appliance R h side blue Cold water inlet L h side red DHW outl...

Page 15: ...iance carries out a new boil dry protection check f f If the fault continues to be displayed reset the appliance P5 on 11 1 1 Appliance handover f f Explain the functions of the appliance to the user...

Page 16: ...replace the strainer 14 3 Opening the appliance Material losses Incorrect handling can damage the BUS connection be tween the programming unit and the main PCB f f Carefully pivot the appliance cover...

Page 17: ...e power cable The power cable must only be replaced by a qualified contractor with an original spare part D0000071890 f f Route the power cable along the cable guide 14 7 Positioning the temperature s...

Page 18: ...Energy conversion efficiency 38 Annual power consumption kWh 489 Default temperature setting C 55 Sound power level dB A 15 Daily power consumption kWh 2 260 15 7 Data table SNE 5 t ECO GB 202135 Hydr...

Page 19: ...those subsidiaries Such guarantee is only grant ed if the subsidiary has issued its own terms of guarantee No other guarantee will be granted We shall not provide any guarantee for appliances acquire...

Page 20: ...Finland STIEBEL ELTRON OY Kapinakuja 1 04600 M nts l Tel 020 720 9988 info stiebel eltron fi www stiebel eltron fi France STIEBEL ELTRON SAS 7 9 rue des Selliers B P 85107 57073 Metz C dex 3 Tel 0387...