INSTALLATION 

 

Installation

10.  Installation

10.1  Appliance installation

26

�0

2�

01

�0

42

4

10.2  Water connection and safety assembly

!

 

Material losses

Carry out all water connection and installation work in 

accordance with regulations.

Cold water line

Galvanised steel, stainless steel, copper and plastic are approved 

materials.
A safety valve is required.

DHW line

Stainless steel, copper and plastic pipework are approved ma-

terials.

!

 

Material losses

When using plastic pipework, observe chapter "Specifica-

tion / Fault conditions".

The temperature setting can be limited by the qualified 

contractor. (see chapter "Settings / Limiting the tempera-

ture selection").

f

f

Connect the hydraulic connections with flat gaskets.

Operate the appliance only with pressure-tested taps.

f

f

Fit the safety assembly in the cold water supply line. Be sure 

to choose the appropriate safety assembly, according to the 

relevant static pressure.

f

f

Observe the information in the installation instructions of the 

safety assembly.

See chapter "Specification / Hydraulic diagram" for the general 

arrangement in schematic form. You can fit the safety assembly in 

various positions to suit the space available but it must be placed 

in the same order as shown. The safety assembly provided in the 

pack is fitted to the cold water supply with the exception of the T&P 

valve which is fitted at the top of the DHW cylinder. DHW cylinder 

relief valve connections should not be used for other purposes. 

No valve should be fitted between the expansion valve and the 

DHW cylinder.

f

f

To obtain a balanced water pressure in the cold water and 

DHW lines, position the cold water outlet directly on the out-

let side of the pressure reducing valve.

f

f

The expansion valve should not respond under normal oper-

ating conditions as the expansion vessel will accommodate 

the water as it expands during the heating process.

f

f

Run the expansion valve outlet and that of the T&P valve to a 

drain via a tundish. The purpose of the tundish is to let water 

be seen should these valves respond. The outlet pipe should 

not exceed 9 metres in length without forming an air break, 

i.e. tundish. The pipe must fall continuously throughout its 

length with no additional 90° bends. It must be heat resist-

ant and discharge to a safe visible position away from any 

electrical devices. The pipe diameter must not be smaller 

than the valve outlet. The two discharge pipes can be joined 

together at the point of discharge into a single tundish if 

required.

10.3  Power connection

 

WARNING Electrocution

Carry out all electrical connection and installation work 

in accordance with relevant regulations.

 

WARNING Electrocution

The connection to the power supply is only permissi-

ble as a permanent connection in conjunction with the 

removable cable grommet. The appliance must be able 

to be separated from the power supply by an isolator 

that disconnects all poles with at least 3 mm contact 

separation.

!

 

Material losses

Observe the type plate. The specified voltage must match 

the mains voltage.

!

 

Material losses

Ensure that the appliance is earthed.

Summary of Contents for SHZ 100 S GB

Page 1: ...OPERATION AND INSTALLATION Wall mounted DHW cylinder SHZ 30 S GB SHZ 50 S GB SHZ 100 S GB SHZ 150 S GB...

Page 2: ...ounting bracket 6 9 3 Preparing the power cable 6 10 Installation 7 10 1 Appliance installation 7 10 2 Water connection and safety assembly 7 10 3 Power connection 7 10 4 Completing the installation 8...

Page 3: ...iance Install a type tested safety valve in the cold water supply line Please note that depending on the static pressure you may also need a pressure re ducing valve Size the drain so that water can d...

Page 4: ...ssure During the heat up pro cess expansion water will drip from the outlet side of the safety valve and or of the T P valve If water continues to drip when heating is completed please inform your qua...

Page 5: ...peration with rapid heat up You can switch on rapid heat up with the corresponding key A remote control can also be installed for this purpose The rapid heat up function stops and will not restart whe...

Page 6: ...sure various safety assemblies and pressure reducing valves are available These type tested safety assemblies protect the appliance against unacceptable excess pressure Pressure tested taps are availa...

Page 7: ...uld not be used for other purposes No valve should be fitted between the expansion valve and the DHW cylinder f f To obtain a balanced water pressure in the cold water and DHW lines position the cold...

Page 8: ...e discharge pipe of the safety assembly with a con stant slope Observe the information in the installation instructions of the safety assembly f f Turn the temperature selector to maximum f f Switch t...

Page 9: ...WARNING Electrocution Before any work on the appliance disconnect all poles of the appliance from the power supply For some maintenance work you must remove the bottom cap If you also need to drain th...

Page 10: ...Height mm 846 816 1126 1521 a20 Appliance Width mm 410 510 510 510 a30 Appliance Depth mm 420 510 510 510 b02 Cable entry I PG 21 PG 21 PG 21 PG 21 b03 Cable entry II PG 11 PG 11 PG 11 PG 11 c01 Cold...

Page 11: ...rsion depth mm 380 380 350 380 16 4 Wiring diagrams and terminals 7 8 9 N L1 L2 L3 5 6 8 7 5 3 2 1 26_02_07_0348 4 6 9 1 Terminal for output changeover 2 Plug in distributor for N conductor 3 Heat con...

Page 12: ..._02_07_0041 1 2 3 K1 Contactor 1 K2 Contactor 2 1 Power OFF contact 2 Off peak tariff meter 3 Peak tariff meter Single circuit operation 1 kW 7 8 9 1 N PE 230 V 2 kW 7 8 9 1 N PE 230 V D0000057900 3 k...

Page 13: ...dish mm 22 28 35 Maximum permissible pressure drop expressed as a length of straight pipe i e no elbows or bends m 9 18 27 Pressure drop of each elbow or bend m 1 0 1 4 1 7 Connection dimensions Safet...

Page 14: ...load 230 V kW 1 4 1 4 1 4 1 4 Rated voltage V 230 230 230 230 Phases 1 N PE 1 N PE 1 N PE 1 N PE Frequency Hz 50 50 50 50 Single circuit operating mode X X X X Dual circuit operating mode X X X X Man...

Page 15: ...ose subsidiaries Such guarantee is only grant ed if the subsidiary has issued its own terms of guarantee No other guarantee will be granted We shall not provide any guarantee for appliances acquired i...

Page 16: ...ja 1 04600 M nts l Tel 020 720 9988 info stiebel eltron fi www stiebel eltron fi France STIEBEL ELTRON SAS 7 9 rue des Selliers B P 85107 57073 Metz C dex 3 Tel 0387 7438 88 Fax 0387 7468 26 info stie...

Reviews: