Safety

INSTALLATION

7.  Safety

Only a qualified contractor should carry out installation, commis-

sioning, maintenance and repair of the appliance.

7.1  General safety instructions

We guarantee trouble-free function and operational reliability 

only if the original accessories and spare parts intended for the 

appliance are used.

7.2  Instructions, standards and regulations

 

Note

Observe all applicable national and regional regulations 

and instructions.

8.  Appliance description

8.1  Standard delivery

Delivered with the appliance:

 

- Mounting bracket (2 pce for appliances with a 150 l nominal 

capacity)

 

- 5 mm spacer (2 pce for above, 2 pce for below)

 

- Installation template

 

- Safety assembly

 

- Expansion vessel, 8 litre

 

- Bracket

 

- Tundish

8.2  Accessories

Depending on the static pressure, various safety assemblies and 

pressure reducing valves are available. These type-tested safety 

assemblies protect the appliance against unacceptable excess 

pressure.
Pressure-tested taps are available as accessories.

9.  Preparations

9.1  Installation site

The appliance is exclusively designed for installation on a solid 

wall. Ensure the wall offers adequate load bearing capacity.
Always install the appliance vertically in a room free from the risk 

of frost and near the draw-off point.

9.2  Wall mounting bracket

f

f

You can use the installation template to transfer the dimen-

sions to the wall.

f

f

Drill the holes and secure the wall mounting bracket with 

screws and rawl plugs. Select fixing materials in accordance 

with the wall construction/condition.

You can compensate for unevenness in the wall with the spacers 

provided.
2 mounting brackets are required for appliances with 150 l nomi-

nal capacity.

26

�0

2�

01

�0

57

2

2

1

1  Lower spacer

2  Upper spacer

9.3  Preparing the power cable

270

120

D

00000

42

05

2

Summary of Contents for SHZ 100 S GB

Page 1: ...OPERATION AND INSTALLATION Wall mounted DHW cylinder SHZ 30 S GB SHZ 50 S GB SHZ 100 S GB SHZ 150 S GB...

Page 2: ...ounting bracket 6 9 3 Preparing the power cable 6 10 Installation 7 10 1 Appliance installation 7 10 2 Water connection and safety assembly 7 10 3 Power connection 7 10 4 Completing the installation 8...

Page 3: ...iance Install a type tested safety valve in the cold water supply line Please note that depending on the static pressure you may also need a pressure re ducing valve Size the drain so that water can d...

Page 4: ...ssure During the heat up pro cess expansion water will drip from the outlet side of the safety valve and or of the T P valve If water continues to drip when heating is completed please inform your qua...

Page 5: ...peration with rapid heat up You can switch on rapid heat up with the corresponding key A remote control can also be installed for this purpose The rapid heat up function stops and will not restart whe...

Page 6: ...sure various safety assemblies and pressure reducing valves are available These type tested safety assemblies protect the appliance against unacceptable excess pressure Pressure tested taps are availa...

Page 7: ...uld not be used for other purposes No valve should be fitted between the expansion valve and the DHW cylinder f f To obtain a balanced water pressure in the cold water and DHW lines position the cold...

Page 8: ...e discharge pipe of the safety assembly with a con stant slope Observe the information in the installation instructions of the safety assembly f f Turn the temperature selector to maximum f f Switch t...

Page 9: ...WARNING Electrocution Before any work on the appliance disconnect all poles of the appliance from the power supply For some maintenance work you must remove the bottom cap If you also need to drain th...

Page 10: ...Height mm 846 816 1126 1521 a20 Appliance Width mm 410 510 510 510 a30 Appliance Depth mm 420 510 510 510 b02 Cable entry I PG 21 PG 21 PG 21 PG 21 b03 Cable entry II PG 11 PG 11 PG 11 PG 11 c01 Cold...

Page 11: ...rsion depth mm 380 380 350 380 16 4 Wiring diagrams and terminals 7 8 9 N L1 L2 L3 5 6 8 7 5 3 2 1 26_02_07_0348 4 6 9 1 Terminal for output changeover 2 Plug in distributor for N conductor 3 Heat con...

Page 12: ..._02_07_0041 1 2 3 K1 Contactor 1 K2 Contactor 2 1 Power OFF contact 2 Off peak tariff meter 3 Peak tariff meter Single circuit operation 1 kW 7 8 9 1 N PE 230 V 2 kW 7 8 9 1 N PE 230 V D0000057900 3 k...

Page 13: ...dish mm 22 28 35 Maximum permissible pressure drop expressed as a length of straight pipe i e no elbows or bends m 9 18 27 Pressure drop of each elbow or bend m 1 0 1 4 1 7 Connection dimensions Safet...

Page 14: ...load 230 V kW 1 4 1 4 1 4 1 4 Rated voltage V 230 230 230 230 Phases 1 N PE 1 N PE 1 N PE 1 N PE Frequency Hz 50 50 50 50 Single circuit operating mode X X X X Dual circuit operating mode X X X X Man...

Page 15: ...ose subsidiaries Such guarantee is only grant ed if the subsidiary has issued its own terms of guarantee No other guarantee will be granted We shall not provide any guarantee for appliances acquired i...

Page 16: ...ja 1 04600 M nts l Tel 020 720 9988 info stiebel eltron fi www stiebel eltron fi France STIEBEL ELTRON SAS 7 9 rue des Selliers B P 85107 57073 Metz C dex 3 Tel 0387 7438 88 Fax 0387 7468 26 info stie...

Reviews: