OpEraTiON
Settings with integral room temperature controller
EN
GL
ISH
www.stiebel-eltron.com
SHF | SHS | SHL |
9
Theses phases are factory-set as follows:
- 08:00 h - 22:00 h: Comfort mode
- 22:00 h - 08:00 h: Setback mode
Note
When time program Pro2 is enabled, the appliance oper-
ates at weekends exclusively in setback mode.
To adapt time programs Pro1 and Pro2 according to your needs,
proceed as follows:
f
f
In the configuration menu, use "+" and "–" to call up the re-
quired time program.
f
f
Press "OK".
The start time for comfort mode is displayed.
f
f
Use "+" and "–" to set the required start time.
f
f
Press "OK".
The end time for comfort mode is displayed.
f
f
Use "+" and "–" to set the required end time.
f
f
Press "OK" to save.
Time program Pro3
You can use time program Pro3 to specify up to 14 separate com-
fort phases which are repeated weekly.
To configure a comfort phase in time program Pro3, proceed as
follows:
f
f
In the configuration menu, use "+" and "–" to call up time
program Pro3.
f
f
Press "OK".
The display shows "3---".
f
f
Press "OK".
A day of the week or a group of days is displayed.
f
f
Use "+" and "–" to select the required day or group of days.
f
f
Press "OK".
The start time for comfort mode is displayed.
f
f
Use "+" and "–" to set the required start time.
f
f
Press "OK".
The end time for comfort mode is displayed.
f
f
Use "+" and "–" to set the required end time.
f
f
Press "OK".
Comfort phase "3-01" has been configured.
f
f
To configure a further comfort phase, use "+" and "–" in time
program Pro3 to select display "3---". Proceed as describe
above.
Note
To reset the selected comfort phases, activate parame-
ter P4.
f
f
Please note that activating parameter P4 resets all
time programs (Pro1, Pro2, Pro3) to the factory set-
ting.
5.3.3 Parameters
You can call up the following parameters:
Display
Description
Options
P1
Room temperature offset
±3 °C | ±5 °F
P2
Time format
12 h | 24 h
P3
Temperature display units
°C | °F
P4
Reset time programs (timer mode).
on | off
P5
Reset relative heating time
on | off
To change the value of a parameter, use "+" and "–" to call up the
relevant parameter. Press "OK".
As soon as the "Editable parameter" symbol appears, you can
change the parameter value with "+" and "–". Press "OK" to save
the selected value.
P1: Room temperature offset
Uneven temperature distribution in the room can result in a dif-
ference between displayed actual temperature I1 and the room
temperature you measure. To compensate for this difference, a
room temperature offset of ±3 °C can be set via parameter P1.
Example: The appliance indicates I1 = 21.0 °C. You have measured
a room temperature of 20.0 °C. There is a difference of 1.0 °C.
f
f
To compensate for the difference, select an offset of P1 = -1.0.
P2: Time format
Parameter P2 allows you to specify whether the time is displayed
in the 12 hour or 24 hour format.
P3: Temperature display units
Parameter P3 is used to specify whether the room temperature is
displayed in degrees Centigrade [°C] or Fahrenheit [°F].
P4: Reset time programs
Activating parameter P4 resets all time programs to the factory
setting.
P5: Reset relative heating time
Activating parameter P5 resets the counter for relative heating
time (I2).
5.3.4 Contractor access
Display
Description
CodE
Contractor access
Note
Some menu items are protected by a code and can only
be accessed and adjusted by a qualified contractor.